Determination of in situ-generated dimethyldioxirane from an aqueous matrix using selected ion monitoring.
نویسندگان
چکیده
There is a growing interest in utilizing in situ-generated dimethyldioxirane (DMDO) as an oxidant for synthetic purposes and bleaching and decontamination applications, but the ability to quantify the organic cyclic peroxide species is often complicated by the presence of other reactive components, peroxymonosulfate and acetone, within the solution matrix. This paper is the first to report the use of a MS method for the quantitation of DMDO from these complex matrices by utilizing an isothermal 30 degrees C GC program in conjunction with selected ion monitoring (SIM). The volatile organic species is sampled from the headspace of closed batch system vials and quantified by measuring the abundance of m/z 74. The method achieves a practical quantitation limit (PQL) for DMDO of 0.033 mM, and methyl acetate is identified as a minor decomposition product from the aqueous sample matrix, contributing 9% towards the overall DMDO measurements. The spectroscopic method makes use of common analytical instrumentation and is capable of measuring other in situ-generated dioxiranes, such as those generated from 2-butanone and [2H6]acetone.
منابع مشابه
Ion Pair Dispersive Liquid-Liquid Microextraction for the Determination of Trace Amounts of Copper(II) in Soil, Multivitamin Tablet, Tea and Water Samples Using Flame Atomic Absorption Spectrometry
Ion pair dispersive liquid- liquid microextraction (IP-DLLME) method combined with flame atomic absorption spectrometry was proposed for the determination of trace amounts of copper(II). By using pyrocatechol violet as chelating agent and cetyltrimethyl ammonium bromide as an ion pairing agent, the trace amount of copper(II) was extracted in chloroform. The factors influencing the formation cop...
متن کاملPolymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions
Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...
متن کاملIn situ activation of a Ni catalyst with Mo ion for hydrogen evolution reaction in alkaline solution
In this study Ni catalyst have been activated during hydrogen evolution reaction (HER) by adding Mo ions into the alkaline electrolyte. After dissolving different amounts of ammonium molybdate in the 1M NaOH as electrolyte, Ni catalyst was used as cathode for HER. Afterwards a comparison between hydrogen overpotential measured in Ni catalyst with and without in situ activation has been made; th...
متن کاملAn electrode immobilized in a graphite matrix with ion pair complex for the determination of diclofenac in pharmaceuticals
A simple, precise, rapid and low-cost potentiometric method for diclofenac determination in pharmaceuticals is proposed. A new diclofenac-sensitive electrode was constructed by incorporating the diclofenac ion pair complex with butyl rhodamine B into graphite matrix. The electrode exhibited a linear response over the concentration range of 1 × 10-4 – 5 × 10-2 mol L-1, a detection limit of 3.9×1...
متن کاملIonic Liquid-based Ultrasound-assisted In-situ Solvent Formation Microextraction and High-performance Liquid Chromatography for the Trace Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples
A green and efficient ionic liquid-based ultrasound-assisted in-situ solvent formationmicroextraction (IL-UA-ISFME) in combination with high-performance liquid chromatographyultravioletdetection (HPLC-UV) has been successfully developed for the trace determination offive selected polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. In thismethod, a hydrophobic ionic liquid (1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of chromatography. A
دوره 1089 1-2 شماره
صفحات -
تاریخ انتشار 2005