SIL Rating Fire Protection Equipment

نویسندگان

  • Richard M. Robinson
  • Kevin J. Anderson
چکیده

SIL's (Safety Integrity Levels) are used by IEC 61508:1998 [1] to characterise the required functional safety of computer control systems. For example, SIL 4, the highest rating is for fly by wire aircraft and weapons systems and track circuited train signalling systems while SIL 2 is typical of certain Programmable Logic Controllers (PLC). Fire control panels have not been SIL rated to date even though certification organisations like Factory Mutual provide SIL for various PLCs in their approvals guides. This paper addresses SIL' derivation/allocation to fire systems and fire control panels in particular.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Congested Public Goods: the Case of Fire Protection

This paper uses a fire protection measure based on a community’s tire insurance rating to estimate the strength of congestion effects for fire protectron services. The empirical results show that the congestion properties of fire protection are much like those of a pure public good. In addition, the paper introduces a new notion of returns to scale for public goods and estimates the relevant pa...

متن کامل

A comparison of fire danger rating systems for use in forests

Fire danger is the resultant of ‘factors affecting the inception, spread and difficulty of control of fires and the damage they cause’ (Chandler et al. 1983). If any of these factors are absent, then there is no fire danger (Cheney and Gould 1995). Fire danger rating is ‘a fire management system that integrates the facets of selected fire danger factors into one or more qualitative or numerical...

متن کامل

ارزیابی ریسک حریق و تعیین کارایی روش های حفاظت فعال و غیر فعال در کاهش ریسک حریق در اتاق کنترل یک ساختمان صنعتی

Introduction: Extensive human and economic losses due to the fire accidents shows the necessity of scientifically dealing with major industrial fires, , investing in the development of fire protection technologies and determination of the most effective techniques to limit damages. This study is conducted to evaluate the effect of active and passive protection methods on reducing the level of f...

متن کامل

To Enhance Fire Safety of Nuclear Power Plant by Improving Fire Alarm System

Fire safety is an important component of the safe operation of nuclear power plant, and is an important aspect of the nuclear safety. The Distributed Intelligent Fire Detect and Alarm System is of high reliability and sensitivity. In this article, some research will be made on how to limit fire damage by improving the system reliability and sensitivity. Fire safety is an important component of ...

متن کامل

Simple indiceS for aSSeSSing fuel moiSture content and fire danger rating

BacKground A number of fire danger rating systems, which integrate selected quantifiable factors contributing to fire danger, have been developed to provide numerical indices relating to fire protection needs. it is important to note that fire danger indices have no real physical manifestation – they are just indices. Calculation of fire danger indices generally rely on information relating to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003