Comparative Study of Single Dose Epidural Morphine and Intermittent Dose Morphine with Bupivacaine in Post Cesarean Analgesia

ثبت نشده
چکیده

results: Each group consisted of 36 patients. Demographic characteristics of two groups were comparable and differences among them were not statistically significant. Mean duration of analgesia was significantly longer in group one patients (16.5 ± 2.5) in comparison to group two patients (11.5 ± 1.5). Mean highest visual analogue scales (VAS scale) was significantly lower (3.2± 0.9) in group one patients in comparison of group two (6.7±0.8) patients. Only 43% patient in group one required supplementary analgesic (Inj Paracetamole/ Diclofenac) and 71% required Inj epidural Morphine / Inj bupivacaine in group two . Mean number of supplementary analgesic required in group one was 0.7 and it was 1.8 in group two. There was no significant difference in nausea, vomiting, itching and pruritis in two groups of patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Epidural neostigmine produces analgesia but also sedation in women after cesarean delivery.

BACKGROUND Intrathecal neostigmine produces analgesia but also nausea, limiting its utility. In contrast, epidural administration of neostigmine has been suggested to produce postoperative analgesia without nausea in nonpregnant patients. The purpose of this study was to examine the dose range for efficacy and side effects of epidural neostigmine in women at cesarean delivery receiving combined...

متن کامل

EFFECTS OF EPIDURAL ANALGESI A WITH LOW-DOSE BUPIVACAINE AND FENTANYL ON THE PROGRESS OF LABOR AND MODE OF DELIVERY

Background and Objective: Epidural analgesia (EA) has been used to relieve labor pain in many obstetric units, yet controversy persists about its effect on progress and outcome in labor. The purpose of the current study was to evaluate the effect of EA on the rate of cervical dilation and myometrial contractility. Methods: In a 6-month period, 36 women who received standardized EA were mat...

متن کامل

Postcesarean epidural morphine: a dose-response study.

UNLABELLED The purpose of this study was to describe the dose-response relationship of epidural morphine for postcesarean analgesia for quality of analgesia and relation to the side effects of pruritus, nausea, and vomiting. Sixty term parturients undergoing nonurgent cesarean delivery were enrolled and randomized to receive a single dose of epidural morphine after delivery (0,1.25, 2.5, 3.75, ...

متن کامل

A comparative study of the effect of caudal dexmedetomidine versus morphine added to bupivacaine in pediatric infra-umbilical surgery

BACKGROUND One of the most commonly used regional anesthetic techniques in pediatric surgeries is the caudal epidural block. Its main disadvantage remains the short duration of action. Hence, different additives have been used. Dexmedetomidine is a potent as well as highly selective α2 adrenergic receptor agonist. The aim of this randomized, double-blinded, study was to compare the duration of ...

متن کامل

Comparative study of continuous extrapleural intercostal nerve block and lumbar epidural morphine in post-thoracotomy pain.

OBJECTIVES To compare the efficacy of continuous extrapleural intercostal nerve block with bupivacaine 0.5% in 1:200,000 epinephrine and continuous lumbar epidural block with morphine in controlling post-thoracotomy pain and to measure serum bupivacaine concentrations during extrapleural infusion. DESIGN A prospective, randomized, controlled trial. SETTING St. Joseph's Hospital, Hamilton, O...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013