Warped Optical-Flow Inter-Frame Reconstruction for Ultrasound Image Enhancement
نویسندگان
چکیده
Problem statement: Optical flow inter-frame enhancement is one of the techniques to improve the quality of ultrasound images by reducing the speckle noise. The performance depends on accuracy of the optical flow inter-frame reconstruction which is a part of the technique. The speckle noise of an ultrasound image forms certain pattern, of which size of the speckle varies depends on the distance from the transducer. Approach: This study proposed that the use of warping technique prior to as well as after the optical flow to improve the accuracy of the optical flow calculation. The warping function was derived to transform the image from circular grid to rectangular grid. Results: The technique was applied to a series of synthetic moving frames generated from actual ultrasound image taken from a patient heart. The technique improved the accuracy of motion vectors generated from the optical flow. The MSE of the reconstructed frame was also smaller using warped technique compared to that of the non-warped technique. Conclusion: The proposed warping operation was shown to be successful in increasing the accuracy of the frame reconstruction for the optical flow inter-frame enhancement technique.
منابع مشابه
Resolution Enhancement by Incorporating Segmentation-based Optical Flow Estimation
In this paper, the problem of recovering a highresolution frame from a sequence of low-resolution frames is considered. High-resolution reconstruction process highly depends on image registration step. Typical resolution enhancement techniques use global motion estimation technique. However, in general, video frames cannot be related through global motion due to the arbitrary individual pixel m...
متن کاملAtrial Septal Defect Tracking in 3D Cardiac Ultrasound
We are working to develop beating-heart atrial septal defect (ASD) closure techniques using real-time 3-D ultrasound guidance. The major image processing challenges are the low image quality and the high frame rate. This paper presents comparative results for ASD tracking in sequences of 3D cardiac ultrasound. We introduce a block flow technique, which combines the velocity computation from opt...
متن کاملNoise Reduction in support-constrained multi-frame blind-deconvolution restorations as a function of the number of data frames and the support constraint sizes (Preprint)
We show that the amount of relative noise reduction in multi-frame blind deconvolution image restorations is greatest for just a few data frames and is a more complicated function of the support constraint sizes. ©2007 Optical Society of America OCIS codes: (100.3020) Image reconstruction-restoration; (100.2980) Image enhancement
متن کاملEstimation of FOE Without Optical Flow for ehicle Lateral Position Detection
In this paper, we propose a new method to estimate the FOE (Focus of Expansion) from moving camera image sequence for vehicle motion understanding, which does not rely on optical flow vectors. Motion understanding of the camera is very important in many applications. Most of the conventional methods for detection and estimation of the position of FOE rely on estimation of optical flow vector in...
متن کاملVideo Inter-frame Forgery Identification Based on Optical Flow Consistency
Identifying inter-frame forgery is a hot topic in video forensics. In this paper, we propose a method based on the assumption that the optical flows are consistent in an original video, while in forgeries the consistency will be destroyed. We first extract optical flow from frames of videos and then calculate the optical flow consistency after normalization and quantization as distinguishing fe...
متن کامل