Resistive-heating and forced-air warming are comparably effective.

نویسندگان

  • Chiharu Negishi
  • Kenji Hasegawa
  • Shihoko Mukai
  • Fumitoshi Nakagawa
  • Makoto Ozaki
  • Daniel I Sessler
چکیده

UNLABELLED Serious adverse outcomes from perioperative hypothermia are well documented. Consequently, intraoperative warming has become routine. We thus evaluated the efficacy of a novel, nondisposable carbon-fiber resistive-heating system. Twenty-four patients undergoing open abdominal surgery lasting approximately 4 h were randomly assigned to warming with 1) a full-length circulating water mattress set at 42 degrees C, 2) a lower-body forced-air cover with the blower set on high, or 3) a three-extremity carbon-fiber resistive-heating blanket set to 42 degrees C. Patients were anesthetized with a combination of continuous epidural and general anesthesia. All fluids were warmed to 37 degrees C, and ambient temperature was kept near 22 degrees C. Core (tympanic membrane) temperature changes among the groups were compared by using factorial analysis of variance and Scheffé F tests; results are presented as means +/- SD. Potential confounding factors did not differ significantly among the groups. In the first 2 h of surgery, core temperature decreased by 1.9 degrees C +/- 0.5 degrees C in the circulating-water group, 1.0 degrees C +/- 0.6 degrees C in the forced-air group, and 0.8 degrees C +/- 0.2 degrees C in the resistive-heating group. At the end of surgery, the decreases were 2.0 degrees C +/- 0.8 degrees C in the circulating-water group, 0.6 degrees C +/- 1.0 degrees C in the forced-air group, and 0.5 degrees C +/- 0.4 degrees C in the resistive-heating group. Core temperature decreases were significantly greater in the circulating-water group at all times after 150 elapsed minutes; however, temperature changes in the forced-air and resistive-heating groups never differed significantly. Even during major abdominal surgery, resistive heating maintains core temperature as effectively as forced air. IMPLICATIONS Efficacy was similar for forced-air and resistive heating, and both maintained intraoperative core temperature far better than circulating-water mattresses. We thus conclude that even during major abdominal surgery, resistive heating maintains core temperature as effectively as forced air.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of forced-air warming and resistive heating.

BACKGROUND Perioperative hypothermia is common during anesthesia and surgery and is accompanied by several complications. Forced-air warming is recognized as an effective procedure to prevent hypothermia. The aim of this study was to compare a resistive heating device with a forced-air warming device. METHODS Prospective randomized trial. SETTING heat transfer laboratory of a University hos...

متن کامل

Warming by resistive heating maintains perioperative normothermia as well as forced air heating.

BACKGROUND Even mild perioperative hypothermia is associated with several severe adverse effects. Resistive heating has possible advantages compared with other active warming systems because it can heat several fields independently. To assess this new warming system, we measured core temperature in patients during surgery who were warmed with circulating water mattresses, forced air covers or r...

متن کامل

Intra-operative rewarming with Hot Dog(®) resistive heating and forced-air heating: a trial of lower-body warming.

Resistive heating is an alternative to forced-air warming which is currently the most commonly used intra-operative warming system. We therefore tested the hypothesis that rewarming rates are similar with Hot Dog(®) (Augustine Biomedical) resistive and Bair Hugger(®) (Arizant) forced-air heating systems. We evaluated 28 patients having major maxillary tumour surgery. During the establishment of...

متن کامل

A randomized comparison of intraoperative PerfecTemp and forced-air warming during open abdominal surgery.

BACKGROUND The PerfecTemp is an underbody resistive warming system that combines servocontrolled underbody warming with viscoelastic foam pressure relief. Clinical efficacy of the system has yet to be formally evaluated. We therefore tested the hypothesis that intraoperative distal esophageal (core) temperatures with the PerfecTemp (underbody resistive) warming system are noninferior to upper-b...

متن کامل

Meta-analysis: effectiveness of forced-air warming for prevention of perioperative hypothermia in surgical patients.

AIM The aim of this study was to evaluate the effectiveness of forced-air warming for preventing perioperative hypothermia. BACKGROUND Perioperative hypothermia commonly occurs in patients receiving anaesthesia during surgeries. However, the effectiveness of warming systems requires verification. DESIGN Systematic review incorporating meta-analysis. DATA SOURCES We searched OVID, PubMed, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 96 6  شماره 

صفحات  -

تاریخ انتشار 2003