RadShield: semiautomated shielding design using a floor plan driven graphical user interface

نویسندگان

  • Matthew C. DeLorenzo
  • Dee H. Wu
  • Kai Yang
  • Isaac B. Rutel
چکیده

The purpose of this study was to introduce and describe the development of RadShield, a Java-based graphical user interface (GUI), which provides a base design that uniquely performs thorough, spatially distributed calculations at many points and reports the maximum air-kerma rate and barrier thickness for each barrier pursuant to NCRP Report 147 methodology. Semiautomated shielding design calculations are validated by two approaches: a geometry-based approach and a manual approach. A series of geometry-based equations were derived giv-ing the maximum air-kerma rate magnitude and location through a first derivative root finding approach. The second approach consisted of comparing RadShield results with those found by manual shielding design by an American Board of Radiology (ABR)-certified medical physicist for two clinical room situations: two adjacent catheterization labs, and a radiographic and fluoroscopic (R&F) exam room. RadShield's efficacy in finding the maximum air-kerma rate was compared against the geometry-based approach and the overall shielding recommendations by RadShield were compared against the medical physicist's shielding results. Percentage errors between the geometry-based approach and RadShield's approach in finding the magnitude and location of the maximum air-kerma rate was within 0.00124% and 14 mm. RadShield's barrier thickness calculations were found to be within 0.156 mm lead (Pb) and 0.150 mm lead (Pb) for the adjacent catheteriza-tion labs and R&F room examples, respectively. However, within the R&F room example, differences in locating the most sensitive calculation point on the floor plan for one of the barriers was not considered in the medical physicist's calculation and was revealed by the RadShield calculations. RadShield is shown to accurately find the maximum values of air-kerma rate and barrier thickness using NCRP Report 147 methodology. Visual inspection alone of the 2D X-ray exam distribution by a medical physicist may not be sufficient to accurately select the point of maximum air-kerma rate or barrier thickness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Nuclear Data Processing and Utilization System for Innovative Reactors

A research and development (R&D) project on a nuclear data processing and utilization system was started in 2002 for a five-year plan for innovative nuclear energy systems such as innovative reactors and accelerator-driven systems. The nuclear data processing and utilization system is being developed to use on a PC-Linux server through the Internet, so that it has a graphic user interface (GUI)...

متن کامل

AIDE: A tool to assist in the design and evaluation of user interfaces

The need for working prototypes, expert user interface designers, or test users can prevent an interface from being evaluated thoroughly before the product is released. Automating any part of the design and evaluation process can help eliminate some usability problems, which translates into reduced development costs. This also allows designers to focus their attention on the more demanding aspe...

متن کامل

Software Implementation and Experimentation with a New Genetic Algorithm for Layout Design

This paper discusses the development of a new GA for layout design. The GA was already designed and reported. However the implementation used in the earlier work was rudimentary and cumbersome, having no suitable Graphical User Interface, GUI. This paper discusses the intricacies of the algorithm and the GA operators used in previous work. It also reports on implementation of a new GA operator ...

متن کامل

Super Event Driven System OOP GUI Design

This article presents a new proposal design of GUI and new technology in programming Namely ‘Super Technology” which can be applied for supporting the proposal design of GUI Keywords— Object Oriented Programming (OOP), Graphical User Interface (GUI), Event Driven System, Embedded System, and new proposal design of GUI.

متن کامل

Measuring Mathematic Formula Writing Competence: An Application of Graphical Protocol Analysis

Graphical protocol analysis (GPA) is a novel method for studying chunk-based cognitive performance using semiautomated analysis of a temporal chunk signal in writing protocols. This study applies GPA to the writing of mathematical equations by participants with different levels of expertise. Multiple levels of competence can be distinguished on a single individual and single task basis.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016