Point-Spread-Functions for RF Imaging with TRASE: Implications for Phase Gradient Coil Design and Flip Angle Calibration
نویسندگان
چکیده
Introduction – TRASE – Imaging without B0-Gradients TRASE is a k-space imaging method which uses RF phase gradients instead of B0-gradients (1). A 1D TRASE sequence consists of excitation followed by an echo train in which the RF refocusing pulses are alternately applied with fields ‘A’ and ‘B’. These 2 fields are ideally of uniform magnitude but with positive and negative B1 phase gradients respectively. This results in k-space evolution occurring from one echo to the next, and sampling of an echo train yields a line of k-space. TRASE is a general k-space method and 2D imaging and slice selection have been demonstrated (1).
منابع مشابه
The intrinsic magnetic field symmetries of the spiral birdcage coil
INTRODUCTION Transmit array spatial encoding (TRASE) is a novel MRI technique that utilizes B1-field phase gradients as the means for traversing k-space [1-3]. This method allows MRI to be performed without the usual application of B0-field amplitude gradients, thereby possibly eliminating the equipment, complexity, power consumption and acoustic noise associated with traditional static-field g...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملParallel imaging with phase scrambling.
PURPOSE Most existing methods for accelerated parallel imaging in MRI require additional data, which are used to derive information about the sensitivity profile of each radiofrequency (RF) channel. In this work, a method is presented to avoid the acquisition of separate coil calibration data for accelerated Cartesian trajectories. METHODS Quadratic phase is imparted to the image to spread th...
متن کاملMeasurement and characterization of RF nonuniformity over the heart at 3T using body coil transmission.
PURPOSE To measure and characterize variations in the transmitted radio frequency (RF) (B1+) field in cardiac magnetic resonance imaging (MRI) at 3 Tesla. Knowledge of the B1+ field is necessary for the calibration of pulse sequences, image-based quantitation, and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) optimization. MATERIALS AND METHODS A variation of the saturated dou...
متن کامل