Combined single-drop and rotating drum dustiness test of fine to nanosize powders using a small drum.

نویسندگان

  • Thomas Schneider
  • Keld Alstrup Jensen
چکیده

A dustiness test has been developed that performs both a single-drop and a continuous rotation test using a 6-g sample. Tests were completed on pigment-grade and ultrafine TiO2, two grades of corundum (Aloxite), yttrium-stabilized zirconia (Y-zirconia) granules, fumed silica, goethite, talc and bentonite. The generated particles were quantified by counting and sizing at 1-s time resolution using the TSI Fast Mobility Particle Sizer and the TSI Aerodynamic Particle Sizer and by collecting the particles on a filter for weighing. The method generated reproducible amounts and size distributions of particles. The size distributions had two more or less separated size modes >0.9 microm and in addition all materials except TiO2 pigment-grade and Aloxite F1200 generated a size mode in the range from approximately 100 to approximately 220 nm. Pigment-grade TiO2 had the lowest dustiness and ultrafine TiO2 the highest dustiness as measured by particle number for both the single-drop and rotation test and as measured by mass for both tests combined. The difference was a factor of approximately 300. Three types of dust generation rate time profiles were observed; brief initial burst (talc, both grades of corundum), decaying rate during rotation period (fumed silica, TiO2 ultrafine and pigment grade, bentonite) and constant rate (Y-zirconia, goethite). These profile types were in agreement with the differences in the ratio of amount of particles generated during the single drop to the amount generated during the single-drop and rotation test combined. The ratio ranged a factor approximately 40. The new test method enables a characterization of dustiness with relevance to different user scenarios.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Size selective dustiness and exposure; simulated workplace comparisons.

A simulated workplace study was conducted to investigate the relation between inhalation exposure and dustiness determined with a rotating drum dustiness tester. Three powders were used in the study, i.e. magnesium stearate, representing a very dusty powder, and aluminium oxide and calcium carbonate, representing low and very low dusty powders, respectively. Two scenarios of handling small volu...

متن کامل

Comment on Comparison of Powder Dustiness Methods

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/ by/3.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. Editorial Note. Letters to the Editor are peer reviewed to ensure that the arguments are reasonable and clearly expresse...

متن کامل

Granular dynamics of cohesive powders in a rotating drum as revealed by speckle visibility spectroscopy and synchronous measurement of forces due to avalanching

We have used speckle visibility spectroscopy (SVS) and synchronized force measurements to compare the granular dynamics of two cohesive lactose powders, with Sauter mean diameters of ~29 μm and ~151 μm, in a rotating drum. A load cell (LC) was used to measure forces on the drum mounting frame and enable monitoring of bulk powder motion; SVS is a dynamic light scattering technique particularly s...

متن کامل

Dustiness of Fine and Nanoscale Powders

Dustiness may be defined as the propensity of a powder to form airborne dust by a prescribed mechanical stimulus; dustiness testing is typically intended to replicate mechanisms of dust generation encountered in workplaces. A novel dustiness testing device, developed for pharmaceutical application, was evaluated in the dustiness investigation of 27 fine and nanoscale powders. The device efficie...

متن کامل

Nonlinear Modelling of Kerman Combined Cycle Power Plant Drum-Boiler and Drum Level control especially in trip conditions

There are various methods of power generation such as combined cycle power plants. There are many variables in a power plant boiler unit, but the most important variables are Pressure and specially drum level that control system should be put it in the safe range. The purpose of this article is, modifying the oscillatory behavior of the drum level of Kerman combined cycle power plant and especi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 52 1  شماره 

صفحات  -

تاریخ انتشار 2008