Pre-operative transthoracic real-time three-dimensional echocardiography for a better surgical strategy.

نویسندگان

  • A Ionac
  • C Mornoş
  • H Feier
  • D Cozma
  • L Petrescu
  • I Popescu
  • G Ionescu
  • M Cocora
  • M Gaspar
  • S I Drăgulescu
چکیده

UNLABELLED In this study we aimed to evaluate the three-dimensional (3D) transthoracic echocardiography (TTE) in the assessment of cardiac valve morphology. METHODS Bidimensional (2D) and real-time 3D TTE was performed in 104 patients consecutive with cardiac catheterisation, prior to valve surgery. Using surgical findings as the gold standard, 2D and 3D TTE were compared for adequate recognition and accurate detection of morphology. A scoring protocol was used for recognition of the valvular segments (0= inadequate, 1 = adequate). RESULTS Adequate echographic visualization of the valve segments was more frequently obtained by 3D than 2D TTE imaging (731/770 by 3D TTE vs. 693/770 by 2D TTE, p < 0.01). The valve leaflets segments were more clearly identified by 3D TTE rather than by 2D TTE (502/531 vs. 471/531, p <0.01). The assessment of commissures was similar by both methods (229/239 vs. 222/239, p=0.09). Total 3D TTE scores for mitral and aortic valves were significantly better than 2D ITE scores (mean score 12.91+/-1.62 by 3D vs 11.58+/-1.02 by 2D, p=0.02). This superiority of 3D TTE was irrespective of rhythm (p <0.05 for both sinus rhythm and atrial fibrillation). Using surgical classification of valvular disease as gold standard, the sensibility and specificity were 91% and 84 % for 3D TTE, and 85% and 77% for 2D TTE, respectively. CONCLUSIONS Real-time 3D was superior to 2D TTE forthe accurate localization and identification of valvular pathology, irrespective of heart rhythm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Usefulness of intraoperative real-time three-dimensional transesophageal echocardiography for pre-procedural evaluation of mitral valve cleft: a case report

A precise pre-procedural evaluation of mitral valve (MV) pathology is essential for planning the surgical strategy for severe mitral regurgitation (MR) and preparing for the intraoperative procedure. In the present case, a 38-year-old woman was scheduled to undergo MV replacement due to severe MR. She had a history of undergoing percutaneous balloon valvuloplasty due to rheumatic mitral stenosi...

متن کامل

Usefulness of live/real time three-dimensional transthoracic echocardiography in the identification of individual segment/scallop prolapse of the mitral valve.

In this report, we present 34 patients in whom surgical intervention was undertaken for severe mitral insufficiency due to mitral valve prolapse (MVP). Location and severity of MVP and regurgitation were assessed preoperatively by live/real time three-dimensional transthoracic echocardiography and closely agreed with the surgical findings.

متن کامل

Real-time three-dimensional transthoracic echocardiography.

BACKGROUND Complex anatomy of intra-cardiac structures requires spatial orientation of image in three dimensions for better understanding and enhanced image interpretation. We evaluated the feasibility and efficacy of the emerging 'real-time three-dimensional transthoracic echocardiography' technique for comprehensive assessment of cardiac anatomy, physiology, pathomorphology and pathophysiolog...

متن کامل

Assessment right atrial thrombus by real-time three dimensional transthoracic echocardiography in patient with dilated cardiomyopathy

We report a case of a 52-year-old patient with dilated cardiomyopathy who presented with worsening heart failure. Two-dimensional transthoracic echocardiography and real-time three dimensional transthoracic echocardiography showed severe dilated cardiac chambers, impaired ejection fraction and a mobile right atrial thrombus 2.6 × 1.0 cm in size, traversing the right atrial cavity during the who...

متن کامل

Real-time 3-dimensional transesophageal echocardiography in the evaluation of post-operative mitral annuloplasty ring and prosthetic valve dehiscence.

OBJECTIVES This study sought to assess the use of real-time (RT) 3-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) in the evaluation of post-operative mitral valve dehiscence. BACKGROUND Mitral valve replacement or repair may be complicated by post-operative dehiscence of the valve or annuloplasty ring resulting in clinically significant mitral regurgitation or hemol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chirurgia

دوره 106 2  شماره 

صفحات  -

تاریخ انتشار 2011