Comparative study of rabbit pyrogen test and human whole blood assay on human serum albumin.

نویسندگان

  • Ingo Spreitzer
  • Matthias Fischer
  • Katja Hartzsch
  • Ursel Lüderitz-Püchel
  • Thomas Montag
چکیده

A comparative study of rabbit pyrogen test and human whole blood assay was performed on released preparations of human serum albumin. In addition, the samples were spiked with 5 IU/ml (in whole blood 0.5 IU/ml too) and 10 IU endotoxin/ml. The unspiked samples were negative in both assays. The human whole blood test resulted in the same level of security for the products as the rabbit pyrogen test did. Both, the borderline 5 IU/kg and the 10 IU/kg-Spike partially lead to results of the rabbit test which would cause further testing with additional animals. In contrast, the human whole blood assay resulted in a 100% detection for the 5 IU/ml and 10 IU/ml-Spike. We designed a study protocol for a minimised number of test animals and were able to show the general usefulness of the human whole blood assay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monocyte activation test (MAT) reliably detects pyrogens in parenteral formulations of human serum albumin.

Disadvantages of the regulatory pyrogen test to assure safety of the end-product Human Serum Albumin (HSA) for parenteral use call for the implementation of an alternative test. In the current study, 16 HSA batches were assayed for pyrogens in parallel with the Rabbit Pyrogen Test, conventional and endotoxin-specific LAL assay and monocyte activation test (MAT). It was found that all HSA batche...

متن کامل

Optimization and novel applications of the in vitro pyrogen test (IPT) using human whole blood

Development, validation and applications of the in vitro pyrogen test (IPT) based on human whole blood (submitted to J Clin Immunol) International validation of novel pyrogen tests based on human monocytoid cells. on cryopreserved human whole blood for lipidic parenterals (Pharmeuropa, in print) on cryopreserved human primary blood cells (J Immunol Methods, in print) Comparison of the reactivit...

متن کامل

Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test

The possibility of replacing the rabbit pyrogen test by the Limulus Amebocyte lysate (LAL) test, as a final release test for Large Volume Parenterals (LVPs) was investigated. The sensitivity and specificity of the LAL test and rabbit pyrogen assay were studied by means of artificially contaminated parenterals. Various LVPs (mostly containing electrolytes) were spiked with 0.5 and 5 EUlml o...

متن کامل

Evaluation of the in vitro pyrogen test system based on proinflammatory cytokine release from human monocytes: comparison with a human whole blood culture test system and with the rabbit pyrogen test.

The reliability of an in vitro pyrogen test system based on proinflammatory cytokine release from human monocytic cells was assessed by comparison with a test system based on a human whole blood culture as well as with the conventional rabbit pyrogen test. The human cells used as the pyrogen indicator cells were newly selected by subcloning of a human monocytic cell line, Mono-Mac-6. The select...

متن کامل

How Do Palladium Complexes Affect on Coil Structure of Human Serum Albumin in the Presence of Carbon Nanotube? A Molecular Dynamics Study

To investigate the interaction and adsorption of drug and carbon nanotube on human serum albumin, three anti-cancer drugs ([Pd(phen)(R-gly)]NO3, R = methyl, propyl and amyl) with different hydrophobic tails and anticancer activities were selected. These drugs have better anti-tumor activity and less side effects than that known cis-platinum drug. Human serum albumin is also ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • ALTEX

دوره 19 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2002