Plain radiographs inadequate for evaluation of the cement-bone interface in the hip prosthesis. A cadaver study of femoral stems.

نویسندگان

  • M E Jacobs
  • E M Koeweiden
  • T J Slooff
  • R Huiskes
  • J R van Horn
چکیده

To determine whether plain radiographs accurately represent the true cement-bone interlock, a comparison was made between radiographs and macroscopic morphology on cross sections of 11 human femora into which a cemented endoprosthesis had been inserted. Four femora had been retrieved postmortem from patients with a hip arthroplasty, and seven cadaver femora were cemented under varying conditions. All the femora were radiographed and then cut for macroscopic inspection of the cement-bone interface with respect to gross interposition, depth of cement penetration, integrity of the bone bed, and lamellation of the cement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A retrieval study of capital hip prostheses with titanium alloy femoral stems.

We have examined 26 retrieved, failed titanium-alloy femoral stems. The clinical details, radiological appearances and the histology of the surrounding soft tissues in each patient were also investigated. The stems were predominantly of the flanged design and had a characteristic pattern of wear. A review of the radiographs showed a series of changes, progressive with time. The first was latera...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

The effect of two different types of cement restrictors on the femoral cement mantle.

Cement restriction and pressurisation are helpful technical points in achieving a good cement mantle in cemented hip replacement. In this prospective study, we compared 39 cases where a Hardinge polyethylene restrictor was used and 33 cases where a bone block restrictor was used during Charnley hip replacement. The preoperative radiographs were templated, calibrated holders for the cement restr...

متن کامل

The posterior approach reduces the risk of thin cement mantles with a straight femoral stem design

BACKGROUND AND PURPOSE The properties of the cement mantle around a prosthesis are important. We investigated whether the surgical approach to the hip influences the quality and thickness of the cement mantle when using a straight femoral stem design. METHODS In a consecutive multi-surgeon series, we reviewed the radiographs of 270 patients after cemented Exeter total hip arthroplasty. 135 st...

متن کامل

Loosening of matt and polished cemented femoral stems.

We have compared prospectively the incidence of loosening of 20 femoral stems with a matt surface with that of 20 polished stems of an otherwise identical tapered, non-modular design of Exeter hip replacement. The stems were inserted using the same technique at operation and radiographs showed no difference in the adequacy of the cement mantle or of fixation. All the patients were reviewed regu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Scandinavica

دوره 60 5  شماره 

صفحات  -

تاریخ انتشار 1989