Residual air in the venous cannula increases cerebral embolization at the onset of cardiopulmonary bypass.
نویسندگان
چکیده
OBJECTIVE When the right atrium (RA) cannula is connected to the venous return line of the cardiopulmonary bypass (CPB) circuit, air is often introduced. Air in the venous cannula may increase cerebral air embolization at initiation of CPB despite the arterial line filter. We measured the volume of air present in the venous cannula after cannulation of the RA. Transcranial Doppler quantified emboli as high-intensity transient-signals (HITS) in both middle-cerebral arteries (MCA) at the beginning of CPB. METHODS After RA cannulation, the air column in the venous line was measured and the total volume calculated using the known lumen diameter. CPB onset was defined as the instant when the CPB machine started moving the patient's blood from the RA into the venous reservoir. Starting from CPB onset, HITS were counted: (a) until completion of the first minute on CPB (1-min count) and (b) until aortic cross clamping (pre-clamping count). RESULTS We studied 135 patients during coronary artery bypass surgery operated on by 10 cardiac surgeons. HITS during onset of CPB were detected in 95% of patients. Median counts were 10 HITS (25th, 75th percentiles: 3, 26) at 1-min and 21 HITS (8, 51) during pre-clamping. A significant correlation was found between the volume of air in the venous cannula and the HITS counts (r=0.524, p<0.0001). Absence of retained air was associated with lower HITS counts [3 HITS (1, 11)] compared with any amount of air [13 HITS (4, 29), p=0.002)]. The volume of air in the venous cannula, the MCA mean blood flow velocity and the pre-clamping time were the only independent predictors of the pre-clamping HITS counts (p<0.001). CONCLUSION Air in the venous cannula can result in HITS in the MCA. Minimizing the volume of air introduced into the venous cannula after cannulation of the RA can decrease cerebral air embolization at the beginning of CPB.
منابع مشابه
Starting Selective Cerebral Perfusion from the Beginning of Cardiopulmonary Bypass to Prevent Cerebral Embolization During Total Arch Replacement
ing cerebral embolization due to detached atherosclerotic material from the ascending and arch aortic intima, caused by the “sandblasting” effect of the high-velocity jet from an aortic cannula. Although the number of cases having pedunculated atheroma, mural thrombus in ascending aorta, or aortic arch is low, I believe this method helps to treat such cases. In addition, the safety of starting ...
متن کاملCaval collapse during cardiopulmonary bypass: a reproducible bench model.
OBJECTIVES During open heart surgery, so-called atrial chatter, a phenomenon due to right atria and/or caval collapse, is frequently observed. Collapse of the cava axis during cardiopulmonary bypass (CPB) limits venous drainage and may result downstream in reduced pump flow on (lack of volume) and upstream in increased after-load (stagnation), which in turn may both result in reduced or even in...
متن کاملAn Unusual Case of Cannula Obstruction Resulting from Venous Thromboembolism.
Cerebral strokes of unknown origin frequently present with a patent foramen ovale (PFO), a common atrial septal defect occurring in approximately 25% of the adult population. Deep vein thrombosis (DVT) or pulmonary embolism (PE) in the presence of a PFO can produce paradoxical systemic embolization subsequent to an increase in pulmonary pressure, permitting entry of thrombi into the arterial ci...
متن کاملPressure and Flow Characteristics of a Novel Bidirectional Cannula for Cardiopulmonary Bypass
OBJECTIVE Femoral arterial cannulation is associated with a significant risk of lower limb ischemia. The aim of the study was to assess the pressure and flow in the femoral artery using a novel bidirectional femoral cannula in a sheep model of peripheral cardiopulmonary bypass. METHODS Peripheral cardiopulmonary bypass was established using a multistage venous cannula inserted into the intern...
متن کاملPlacement of a modified cannula in the innominate vein for sufficient drainage during the bidirectional Glenn shunt procedure without cardiopulmonary bypass
During the bidirectional Glenn shunt procedure in small infants, the standard right-angle venous cannula is frequently placed in the innominate vein for establishing the temporary veno-atrial bypass without cardiopulmonary bypass, but it should be small enough to allow flow to pass around it from the internal jugular vein opposite to the side the cannula is directed. Small cannula may induce th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 29 2 شماره
صفحات -
تاریخ انتشار 2006