Chemiluminescence immunoassay of cyclosporine in whole blood.
نویسندگان
چکیده
We describe a chemiluminescent immunoassay (CLI) for measuring cyclosporine in whole blood. Its sensitivity and accuracy are comparable with those of an RIA method that makes use of the same specific monoclonal antibody. The comparison with the RIA method was excellent: y(RIA) = x(CLI) + 11.24 (r = 0.99). In our procedure the samples are incubated with cyclosporin C-hemisuccinate-aminobutyl-N-ethylisoluminol, antibody, and paramagnetic particles coated with second antibody. After magnetic separation and washing, the samples are incubated with 200 microL of NaOH (2 mol/L) at 60 degrees C for 30 min. The chemiluminescence generated by automated serial injections of solutions of microperoxidase and dilute (2 mL/L) H2O2 is measured for 5 s. The data are processed by using a spline fit of log B/Bo log conversion. This method is easy to perform and avoids the hazards and costs associated with isotopic waste disposal. The label is stable for at least three years.
منابع مشابه
Analytical performance evaluation of the Elecsys® Cyclosporine and Elecsys® Tacrolimus assays on the cobas e411 analyzer
BACKGROUND Cyclosporine (CsA) and tacrolimus (TAC) are immunosuppressant drugs that are often used to treat autoimmune diseases and as transplantation therapy; therefore, their concentrations need to be monitored carefully. We herein evaluated the analytical performance of the Elecsys® Cyclosporine and Elecsys® Tacrolimus assay kits, which have been newly developed to measure CsA and TAC concen...
متن کاملComparison between ultra-performance liquid chromatography with tandem mass spectrometry and a chemiluminescence immunoassay in the determination of cyclosporin A and tacrolimus levels in whole blood
Regular immunosuppressant drug monitoring is important for maintaining the drug concentrations of organ recipients within the therapeutic range. The standardized liquid chromatography-tandem mass spectrometry (LC-TMS) technique has been used for the accurate analysis of immunosuppressive drugs. In the present study, the performance of the recently developed high-throughput, rapid ultra-performa...
متن کاملLaboratory Monitoring of Cyclosporine Pre-dose Concentration (C0) After Kidney Transplantation in Isfahan
Background: Cyclosporine is the main immunosuppressive agent used in organ transplantation which leads to considerable improvement in graft survival. The large inter- and intra- patient variability in cyclosporine pharmacokinetics coupled with the agent’s narrow therapeutic index and adverse effects necessitate therapeutic monitoring of cyclosporine blood levels. Objective: The aim of this stu...
متن کاملAbbott's fluorescence polarization immunoassay for cyclosporine and metabolites compared with the Sandoz "Sandimmune" RIA.
A new procedure for measuring cyclosporine in plasma has been introduced by Abbott Laboratories, involving their TDx instrumentation and fluorescence polarization immunoassay. Radioimmunoassay (RIA) and high-performance liquid chromatography are currently the conventional methods for measuring cyclosporine in plasma and whole blood. In an effort to find a method that will decrease the radioacti...
متن کاملClinical Chemistry / CYCLOSPORINE METABOLISM IN TRANSPLANT RECIPIENTS
Cyclosporine is used in the prevention of allograft rejection. Owing to its narrow therapeutic index, regular monitoring of the whole blood levels of cyclosporine is required. We observed that immunoassays measured significantly higher cyclosporine levels than did high-performance liquid chromatography (HPLC) over time after transplantation. As cyclosporine metabolites crossreact even with immu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 36 6 شماره
صفحات -
تاریخ انتشار 1990