MR line-scan diffusion imaging of the spinal cord in children.
نویسندگان
چکیده
Diffusion imaging has been widely used in the brain, but its application in the spinal cord has been limited. Using line-scan diffusion imaging (LSDI), a technique that is less sensitive to magnetic susceptibility and motion artifacts than are other diffusion techniques, we have successfully imaged the spinal cord in children. The apparent diffusion coefficient and relative diffusion anisotropy of the normal spinal cord were measured. LSDI was compared with echo-planar diffusion imaging of the spine in three patients.
منابع مشابه
Restricted diffusion in spinal cord infarction demonstrated by magnetic resonance line scan diffusion imaging.
BACKGROUND AND PURPOSE We report on the use of line scan diffusion magnetic resonance imaging in the evaluation of spinal cord infarctions. METHODS Data on 19 patients with clinical findings consistent with spinal cord infarctions and abnormal findings on line scan diffusion imaging were reviewed. The Apparent Diffusion Coefficient (ADC) measurements for the normal spinal cord and for the are...
متن کاملBrief Reports Restricted Diffusion in Spinal Cord Infarction Demonstrated by Magnetic Resonance Line Scan Diffusion Imaging
Background and Purpose—We report on the use of line scan diffusion magnetic resonance imaging in the evaluation of spinal cord infarctions. Methods—Data on 19 patients with clinical findings consistent with spinal cord infarctions and abnormal findings on line scan diffusion imaging were reviewed. The Apparent Diffusion Coefficient (ADC) measurements for the normal spinal cord and for the areas...
متن کاملLine scan diffusion tensor MRI of the cervical spinal cord in preterm infants.
Line scan diffusion tensor magenetic resonance imaging (DT-MRI) of the cervical spinal cord was demonstrated in vivo for unsedated preterm (gestational age 24-30 weeks at birth), very low birthweight (birthweight 620-1300 g) infants at postmenstrual ages from 29-40 weeks. Scalar invariant measures of diffusion [apparent diffusion coefficient (ADC) and relative anisotropy (RA)] determined from a...
متن کاملOptimized co-registration method of Spinal cord MR Neuroimaging data analysis and application for generating multi-parameter maps
Introduction: The purpose of multimodal and co-registration In MR Neuroimaging is to fuse two or more sets images (T1, T2, fMRI, DTI, pMRI, …) for combining the different information into a composite correlated data set in order to visualization, re-alignment and generating transform to functional Matrix. Multimodal registration and motion correction in spinal cord MR Neuroimag...
متن کاملClinical Relevance of Mr Spectroscopy in the Spinal Cord
SUMMARY: MR spectroscopy allows insight into the chemical composition of human tissue noninvasively. Thereby it can help to better characterize pathologic processes affecting the spinal cord andmay provide important clinicalmarkers for differential diagnosis. However, due to technical challenges, it has been rarely applied to the spinal cord. The aim of this review was to summarize the technica...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 21 7 شماره
صفحات -
تاریخ انتشار 2000