Molecular normalization of dystrophin in the failing left and right ventricle of patients treated with either pulsatile or continuous flow-type ventricular assist devices.
نویسندگان
چکیده
OBJECTIVES We investigated the integrity of dystrophin in left ventricle (LV) and right ventricle (RV) of patients with end-stage heart failure due to ischemic cardiomyopathy (IHD) or dilated cardiomyopathy (DCM), and compared the efficacy of pulsatile or continuous flow assist devices on dystrophin reverse remodeling. BACKGROUND Recently we demonstrated that the amino (N)-terminus of dystrophin is preferentially disrupted in failing LV myocardium irrespective the underlying etiology, and that this defect is reversed by mechanical unloading using left ventricular assist device (LVAD) therapy. METHODS Myocardial samples were obtained from seven normal controls, seven failing hearts (either DCM or IHD), and 14 failing-heart patients who underwent placement of either pulsatile (7 patients) or continuous flow (7 patients) LVADs for progressive refractory HF. The expression and integrity of dystrophin in these samples were determined by immunohistochemistry using antibodies against the N-terminal and carboxyl (C)-terminal domains. RESULTS Immunohistochemical staining identified disruption of the N-terminal dystrophin in both LVs and RVs of all seven failing-heart patients, whereas the C-terminus was normal. Furthermore, this disruption was reversed in 12 of the 14 patients after LVAD therapy using either pulsatile or continuous devices; the degree of the reverse remodeling was similar in both ventricles, although greater recovery was noted in patients treated with pulsatile flow devices. CONCLUSIONS Integrity of the N-terminus of dystrophin is a useful indicator of both LV and RV function. In addition to improving LV hemodynamics, LVAD therapy results in amelioration of the myocardial structure of the right cardiac chamber.
منابع مشابه
Is flow really continuous in last generation continuous flow Ventricular Assist Devices? A comparison between HeartMate II and HeartWare HVAD
HSR Proceedings in Intensive Care and Cardiovascular Anesthesia 2011, Vol. 4 Corresponding author: Giulio Melisurgo Cardiovascular and Thoracic Department Università Vita-Salute San Raffaele Via Olgettina, 60 20132 Milan, Italy e-mail: [email protected] Continuous-flow ventricular assist devices (VADs) are the standard of care for implantable mechanical circulatory support (1). However, s...
متن کاملLeft ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates.
OBJECTIVE Fixed pulmonary hypertension is a contraindication for cardiac transplantation because of the increased risk of donor heart failure. We sought to determine whether left ventricular assist devices improve fixed pulmonary hypertension in cardiac transplant candidates to enable safe cardiac transplantation. METHODS Thirty-five consecutive cardiac transplant candidates (age 56 +/- 6 yea...
متن کاملA mathematical model to evaluate control strategies for mechanical circulatory support.
Continuous flow ventricular assist devices (VADs) for mechanical circulatory support (MCS) are generally smaller and believed to be more reliable than pulsatile VADs. However, regarding continuous flow, there are concerns about the decreased pulsatility and ventricular unloading. Moreover, pulsatile VADs offer a wider range in control strategies. For this reason, we used a computer model to eva...
متن کاملContinuous flow left ventricular assist devices: a valid option for heart failure patients.
Recent outstanding clinical advances with new mechanical circulatory systems (MCS) have led to additional strategies in the treatment of end stage heart failure (HF). Heart transplantation (HTx) can be postponed and for certain patients even replaced by smaller implantable left ventricular assist devices (LVAD). Mechanical support of the failing left ventricle enables appropriate hemodynamic st...
متن کاملMathematical analysis of the effects of valvular regurgitation on the pumping efficacy of continuous and pulsatile left ventricular assist devices
BACKGROUND A left ventricular assist device (LVAD) is normally contraindicated in significant aortic regurgitation (AR) and requires intraoperative valve repair or exclusion. Nevertheless, AR can coexist with an LVAD, so a valid question when asked might still be of clinical significance. The purpose of this study is to analyze the effects of valve regurgitation on the pumping efficacy of conti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 43 5 شماره
صفحات -
تاریخ انتشار 2004