Finite element method analysis of stress distribution to supporting tissues in a Class IV Aramany removable partial denture (Part II: bone and mucosal membrane).
نویسندگان
چکیده
AIM One of the most important issues in the design of removable partial dentures (RPD) is the location of retentive arms to provide sufficient support. This is a critical factor in patients with less supporting tissue and abutment teeth. Patients classified as Class IV Aramany need special attention in this area of RPD design to minimize the stress distribution in bone and mucosal membrane. Using the finite element method, the aim of this study was to analyze the distribution stress to supporting tissues when a Class IV Aramany RPD is worn. The data presented in this report are the effects of the stress on bone and mucosal membranes. Results on teeth and the periodontal ligament have been previously reported. METHODS AND MATERIALS Three dimensional finite element models were constructed using normal dimensions. Exact physiology and morphology of teeth and the remaining palate were simulated to that of a maxillectomy patient. Three RPD designs with circumferential cast retainers were examined: buccal retention and palatal reciprocation (P1); palatal retention and buccal reciprocation (P2); and buccal and palatal retention (P3). After completion of the models and remaining palate, each RPD design was loaded under 53N and stress was applied in three different directions: vertical to the posterior teeth (premolar and first molars) of the RPD (F1); at a 33 masculine angle to the posterior teeth (premolar and first molars) of the RPD (F2); and vertically on the anterior teeth (central incisors) of the RPD (F3). The stress distribution in the RPD models on cortical and cancellous bone and the mucosal membrane was analyzed using von Mises criterion. RESULTS The maximum tension in cortical bone (70.84 Mpa) was observed when a 53N force was applied in a vertical direction to posterior teeth (F2) using buccal and palatal retention (P3). Minimum tension (15.73 Mpa) in cortical bone was observed using the F3 load on the P2 design. Similar results were seen in cancellous bone, with the highest stress (8.01 Mpa) observed using F2 load on the P3 design and the lowest stress (3.04 Mpa) observed using the F3 load on the P2 design. For mucosal membrane, the maximum (3.57 Mpa) and minimum (3.05 Mpa) stress was observed using the F3 load on the P3 design and the F1 load on the P2 design, respectively. The average stress in all RPD designs was 3 Mpa. CONCLUSION The design demonstrating the least tension in cortical and cancellous bone and mucosal membrane was the P2 design, a RPD with palatal retention and buccal reciprocation. CLINICAL SIGNIFICANCE Palatal retention and buccal reciprocation (P2 design) is recommended for patients with maxillofacial RPDs.
منابع مشابه
Finite element method analysis of the stress distribution to supporting tissues in a Class IV Aramany removable partial denture (Part I: the teeth and periodontal ligament).
AIM Special care is required in the fabrication of a Class IV Aramany removable partial denture (RPD) in order to minimize the stress distribution to supporting tissues. Using the finite element method, the aim of this study was to analyze the distribution stress to supporting tissues when a Class IV Aramany RPD is worn. METHODS AND MATERIALS Three RPD designs with circumferential cast retain...
متن کاملEffect of pontic width on stress distribution in abutment teeth and their supporting structures by finite element analysis
Effect of pontic width on stress distribution in abutment teeth and their supporting structures by finite element analysis Dr. J. Ghanbarzadeh* - Dr. MR. Sabooni* - Dr. M. Keshavarz** * Assistant Professor of Dental Prostheses Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. ** Assistant Professor of Dental Prostheses Dept., Faculty of Dentistry, Kerman University of Medical...
متن کاملInfluence of Implant Position on Stress Distribution in Implant-Assisted Distal Extension Removable Partial Dentures: A 3D Finite Element Analysis
OBJECTIVE Distal extension removable partial denture is a prosthesis with lack of distal dental support with a 13-fold difference in resiliency between the mucosa and the periodontal ligament, resulting in leverage during compression forces. It may be potentially destructive to the abutments and the surrounding tissues. The aim of this study was to assess the effect of implant location on stres...
متن کاملEffect of the Number of Implants on Stress Distribution of Anterior Implant-Supported Fixed Prostheses Combined with a Removable Partial Denture: A Finite Element Analysis
OBJECTIVE The main goal of this study was to evaluate differences in stress distribution relevant to the number of implants under an anterior bridge when combined with a removable partial denture in the posterior region. MATERIALS AND METHODS Four three-dimensional finite element models (3D FEM) were designed from a mandible containing an implant-supported bridge extending between canines, an...
متن کاملInvestigating the Stress Distribution Applied to Edentulous Ridge from Polyamide and Cobalt-Chrome Removable-Partial-Dentures using Three-Dimensional Finite-Element-Analysis
Abstract: Objective: The objective of this study was to compare the Von-Mises-stress (VMS) distribution applied to the edentulous ridges from a Polyamide RPD (PRPD) with those from a Cobalt-Chrome RPD (CCRPD). Materials and Methods: A patient with mandibular Kennedy Class I, Mod I was selected. The patientchr(chr('39')39chr('39'))s CBCT was cut off at 1 mm sections from the axial dimension. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of contemporary dental practice
دوره 9 7 شماره
صفحات -
تاریخ انتشار 2008