Subsurface diffuse optical tomography can localize absorber and fluorescent objects but recovered image sensitivity is nonlinear with depth.

نویسندگان

  • Dax S Kepshire
  • Scott C Davis
  • Hamid Dehghani
  • Keith D Paulsen
  • Brian W Pogue
چکیده

Subsurface tomography with diffuse light has been investigated with a noncontact approach to characterize the performance of absorption and fluorescence imaging. Using both simulations and experiments, the reconstruction of local subsurface heterogeneity is demonstrated, but the recovery of target size and fluorophore concentration is not linear when changes in depth occur, whereas the mean position of the object for experimental fluorescent and absorber targets is accurate to within 0.5 and 1.45 mm when located within the first 10 mm below the surface. Improvements in the linearity of the response with depth appear to remain challenging and may ultimately limit the approach to detection rather than characterization applications. However, increases in tissue curvature and/or the addition of prior information are expected to improve the linearity of the response. The potential for this type of imaging technique to serve as a surgical guide is highlighted.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tumor localization using diffuse optical tomography and linearly constrained minimum variance beamforming.

We present a tumor localization method for diffuse optical tomography using linearly constrained minimum variance (LCMV) beamforming. Beamforming is a spatial filtering technique where signals from certain directions can be enhanced while noise and interference from other directions are suppressed. In our method, we tessellate the domain into small voxels and regard each voxel as a possible pos...

متن کامل

Improving depth resolution of diffuse optical tomography with a layer-based sigmoid adjustment method.

Diffuse optical tomography (DOT) has much lower sensitivity in deep tissues than in superficial tissues, which leads to poor depth resolution. In this paper, a layer-based sigmoid adjustment (LSA) method is proposed for reducing sensitivity contrast in the depth dimension. Using this method, differences in image quality between layers can be effectively reduced. As a result, positioning errors ...

متن کامل

An Efficient Method for Model Reduction in Diffuse Optical Tomography

We present an efficient method for the reduction of model equations in the linearized diffuse optical tomography (DOT) problem. We first implement the maximum a posteriori (MAP) estimator and Tikhonov regularization, which are based on applying preconditioners to linear perturbation equations. For model reduction, the precondition is split into two parts: the principal components are consid...

متن کامل

Sub-surface Diffuse Fluorescence Tomography: System Development and Feasibility Studies

Sub-surface tomography with diffuse light has been investigated with a non-contact approach to characterize the performance of optical absorption and fluorescence imaging. Using both simulations and experimental studies, the reconstructed images of local sub-surface heterogeneities was demonstrated, using diffusion properties characteristic of near-infrared light in mammalian tissue. The result...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 46 10  شماره 

صفحات  -