Subsurface diffuse optical tomography can localize absorber and fluorescent objects but recovered image sensitivity is nonlinear with depth.
نویسندگان
چکیده
Subsurface tomography with diffuse light has been investigated with a noncontact approach to characterize the performance of absorption and fluorescence imaging. Using both simulations and experiments, the reconstruction of local subsurface heterogeneity is demonstrated, but the recovery of target size and fluorophore concentration is not linear when changes in depth occur, whereas the mean position of the object for experimental fluorescent and absorber targets is accurate to within 0.5 and 1.45 mm when located within the first 10 mm below the surface. Improvements in the linearity of the response with depth appear to remain challenging and may ultimately limit the approach to detection rather than characterization applications. However, increases in tissue curvature and/or the addition of prior information are expected to improve the linearity of the response. The potential for this type of imaging technique to serve as a surgical guide is highlighted.
منابع مشابه
Tumor localization using diffuse optical tomography and linearly constrained minimum variance beamforming.
We present a tumor localization method for diffuse optical tomography using linearly constrained minimum variance (LCMV) beamforming. Beamforming is a spatial filtering technique where signals from certain directions can be enhanced while noise and interference from other directions are suppressed. In our method, we tessellate the domain into small voxels and regard each voxel as a possible pos...
متن کاملImage quality improvement of diffuse optical tomography of breast tumor using artificial intelligence
This article has no abstract.
متن کاملImproving depth resolution of diffuse optical tomography with a layer-based sigmoid adjustment method.
Diffuse optical tomography (DOT) has much lower sensitivity in deep tissues than in superficial tissues, which leads to poor depth resolution. In this paper, a layer-based sigmoid adjustment (LSA) method is proposed for reducing sensitivity contrast in the depth dimension. Using this method, differences in image quality between layers can be effectively reduced. As a result, positioning errors ...
متن کاملAn Efficient Method for Model Reduction in Diffuse Optical Tomography
We present an efficient method for the reduction of model equations in the linearized diffuse optical tomography (DOT) problem. We first implement the maximum a posteriori (MAP) estimator and Tikhonov regularization, which are based on applying preconditioners to linear perturbation equations. For model reduction, the precondition is split into two parts: the principal components are consid...
متن کاملSub-surface Diffuse Fluorescence Tomography: System Development and Feasibility Studies
Sub-surface tomography with diffuse light has been investigated with a non-contact approach to characterize the performance of optical absorption and fluorescence imaging. Using both simulations and experimental studies, the reconstructed images of local sub-surface heterogeneities was demonstrated, using diffusion properties characteristic of near-infrared light in mammalian tissue. The result...