High-throughput determination of nicotine in plasma by ultrasonication enhanced hollow fiber liquid-phase microextraction prior to gas chromatography.

نویسندگان

  • Xiaotian Liu
  • Shumei Liang
  • Jie Pan
  • Yugao Guo
  • Huiru Luo
  • Qingsong Zhao
  • Shan Guan
چکیده

In high-throughput ultrasonication enhanced hollow-fiber liquid-phase microextraction (H-U-HF-LPME), ultrasonication was introduced into HF-LPME to enhance the mass transfer rate of the analytes in the two immiscible liquid phases, which resulted in a very short time for extraction equilibrium and a high-throughput analysis. Several parameters were investigated and optimized (such as extraction solvent, temperature of sample, frequency and intensity of ultrasonication, volume of extractant, extraction time, ionic strength of the sample and sample concentration). Based on the results of this study, nicotine was first extracted from a 1.5 mL sample solution under the optimum conditions (ultrasonic power of 50 W with a frequency of 60 kHz, extraction time of 10 min, sodium chloride concentration of 5 mol/L and temperature of 37°C). Next, 0.5 µL of acceptor solution inside the hollow fiber was automatically injected into a gas chromatograph with a flame ionization detector. The results of this study illustrated that the limit of detection, relative standard deviation (n = 6), relative recovery and enrichment factor of nicotine were 0.06 µg/L, 3%, 99.8% and 16.6, respectively. Finally, H-U-HF-LPME was successfully applied for the determination of nicotine in plasma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Simple and Efficient Method for Preconcentration and Determination of Trace Levels of Fexofenadine in Plasma and Urine Samples

A simple, inexpensive and sensitive three-phase hollow fiber liquid-phase microextraction (HFLPME) coupled with high performance liquid chromatography (HPLC) with UV detection was successfully developed for determination of trace level of an anti-Histamine drug, fexofenadine, in human plasma and urine. The analyte was extracted into n-octanol that was immobilized in the wall of a porous hollow ...

متن کامل

Microextraction and Determination of Diclofenac in Biological Samples using Hollow Fiber Liquid Phase Microextraction Technique Coupled with HPLC-UV

In this study, hollow fiber liquid phase microextraction (HF-LPME) coupled with highperformanceliquid chromatography (HPLC) with UV detection was applied for preconcentrationand determination of Diclofenac sodium in biological fluids. Parameters affecting the extractionprocess including pH of donor phase and acceptor phase, type of extraction solvent, stirring rate,extraction time, and salt add...

متن کامل

Screening Method for Mononitrotoluenes in Natural Waters Using Magnetic Solvent Bar Liquid-Phase Micro-extraction Followed by Gas Chromatography-Flame Ionization Detection

A simple andefficient hollow fiber-based method,viz magnetic solvent bar liquid-phasemicroextraction (MSB-LPME) combined with gas chromatography-flame ionization detection (GCFID)has been successfully developed for the trace determination of mononitrotoluenes (MNTs) innatural water samples. The analytes were extracted from sample solution to the organic solventimmobilize...

متن کامل

Detection and Determination of some Migrated Chemicals from Plastic Containers into Different Drinks and Liquids Using Dispersive Liquid-liquid Microextraction Prior to Gas Chromatography

Migration of chemicals from plastic containers into drinks and liquids containing them, is supposed to be a hazardous phenomenon and results in many health problems. Sample preparation is of great importance due to trace amounts analysis of these compounds. In this research, dispersive liquid–liquid microextraction is applied for the extraction and preconcentration of the migrated compounds pri...

متن کامل

Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 52 6  شماره 

صفحات  -

تاریخ انتشار 2014