Thin-layer agarose electrophoresis of lactate dehydrogenase isoenzymes in serum: a note on the method of reporting and on the lactate dehydrogenase isoenzyme-1/isoenzyme-2 ratio in acute myocardial infarction.
نویسندگان
چکیده
We assessed the clinical efficacy of a thin-layer agarose electrophoresis assay for lactate dehydrogenase isoenzyme estimation in the diagnosis of acute myocardial infarction. From a population of 228 patients admitted to the Coronary Care Unit with suspected acute myocardial infarction, all 101 positive cases (confirmed by clinical presentation and electrocardiographic changes) were correctly identified with lactate dehydrogenase isoenzyme-1 percentage of total activity above the reference range and with a lactate dehydrogenase isoenzyme-1/isoenzyme-2 ratio of 0.76 or above. This ratio was between 0.45 and 0.74 for 250 healthy subjects. No falsely negative, but 12 falsely positive results were obtained from this Coronary Care Unit population, to give a sensitivity of 100% and a specificity of 90.5% for the ratio test.
منابع مشابه
Glucose estimated with a Beckman Glucose Analyzer 2 in spots of capillary blood on filter paper.
1. Papadopoulos, N. M., and Hufnagel, C. A., Evaluation of lactate dehydrogenase isoenzyme patterns in serum of patients undergoing cardiac surgery. J. Thorac. Cardiovasc. Surg. 76, 173-177 (1978). 2. McKenzie, D., Clarke, P. I., and Henderson, A. R., How accurate are lactate dehydrogenase isoenzyme estimations by the thin-layer agarose fluorescent technique? Clin. Chem. 22, 1995-1998 (1976). 3...
متن کاملGlucose Estimated with a Beckman Glucose Analyzer 2 In Spots of Capillary Blood on Filter
1. Papadopoulos, N. M., and Hufnagel, C. A., Evaluation of lactate dehydrogenase isoenzyme patterns in serum of patients undergoing cardiac surgery. J. Thorac. Cardiovasc. Surg. 76, 173-177 (1978). 2. McKenzie, D., Clarke, P. I., and Henderson, A. R., How accurate are lactate dehydrogenase isoenzyme estimations by the thin-layer agarose fluorescent technique? Clin. Chem. 22, 1995-1998 (1976). 3...
متن کاملInfluence of hemolysis on the serum lactate dehydrogenase-1/lactate dehydrogenase-2 ratio as determined by an accurate thin-layer agarose electrophoresis procedure.
The accuracy of our lactate dehydrogenase (EC 1.1.1.27) isoenzyme procedure, based on electrophoresis in thin-layer agarose, has previously been assessed (Clin. Chem. 22: 1995, 1976). We now show that the method is similarly accurate and precise for the specific measurements of lactate dehydrogenase isoenzyme-1 and -2. We have also determined the lactate dehydrogenase isoenzyme pattern in perip...
متن کاملSimultaneous separation of serum creatine kinase and lactate dehydrogenase isoenzymes by ion-exchange column chromatography.
Lactate dehydrogenase isoenzymes were partially separated by use of a previously described column technique for creatine kinase [Clin. Chem. 20, 36 (1974)]. Extracts of lactate dehydrogenase-rich tissues were used to evaluate column resolution. Samples layered on mini-columns containing DEAE-Sephadex were eluted with Tris-buffered sodium chloride (100 and 200 mmol/liter). Lactate dehydrogenase ...
متن کاملLactate dehydrogenase isoenzyme 1 as determined by inhibition with 1,6-hexanediol and by two other methods in patients with myocardial infarction or cardiac-bypass surgery.
In this assay for lactate dehydrogenase (EC 1.1.1.27) isoenzyme 1 (LD-1), 1,6-hexanediol is added to serum after total LD has been measured. After incubation for 5 min the total LD remaining is determined. Samples from patients who had a myocardial infarction or who had undergone bypass surgery were assayed simultaneously by the 1,6-hexanediol method, the Roche "Isomune LD," and by electrophore...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 25 2 شماره
صفحات -
تاریخ انتشار 1979