چکیده

Porous polyurethane foam was evaluated to replace the eight nylon meshes used as a substrate to collect nanoparticles in the Nanoparticle Respiratory Deposition (NRD) sampler. Cylindrical (25-mm diameter by 40-mm deep) foam with 110 pores per inch was housed in a 25-mm-diameter conductive polypropylene cassette cowl compatible with the NRD sampler. Pristine foam and nylon meshes were evaluated for metals content via elemental analysis. The size-selective collection efficiency of the foam was evaluated using salt (NaCl) and metal fume aerosols in independent tests. Collection efficiencies were compared to the nanoparticulate matter (NPM) criterion and a semi-empirical model for foam. Changes in collection efficiency and pressure drop of the foam and nylon meshes were measured after loading with metal fume particles as measures of substrate performance. Substantially less titanium was found in the foam (0.173 μg sampler-1) compared to the nylon mesh (125 μg sampler-1), improving the detection capabilities of the NRD sampler for titanium dioxide particles. The foam collection efficiency was similar to that of the nylon meshes and the NPM criterion (R2 = 0.98, for NaCl), although the semi-empirical model underestimated the experimental efficiency (R2 = 0.38). The pressure drop across the foam was 8% that of the nylon meshes when pristine and changed minimally with metal fume loading (~ 19 mg). In contrast, the pores of the nylon meshes clogged after loading with ~ 1 mg metal fume. These results indicate that foam is a suitable substrate to collect metal (except for cadmium) nanoparticles in the NRD sampler.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of the Human Extrathoracic Deposition Fraction of Inhaled Particles Using a Polyurethane Foam Collection Substrate in an IOM Sampler

Extrathoracic deposition of inhaled particles (i.e., in the head and throat) is an important exposure route for many hazardous materials. Current best practices for exposure assessment of aerosols in the workplace involve particle size selective sampling methods based on particle penetration into the human respiratory tract (i.e., inhalable or respirable sampling). However, the International Or...

متن کامل

Development of a sampler to estimate regional deposition of aerosol in the human respiratory tract.

A multistage sampler was developed and tested to estimate regional deposition of aerosol in the human respiratory system. The motivation for this research is to improve our ability to estimate inhaled aerosol dose. Current methods for aerosol measurement and exposure/risk assessment are based on particle aspiration (e.g. inhalable PM) or on penetration to various regions of the respiratory syst...

متن کامل

Optimization of the electrospinning process of polyurethane nanofibers and their filtration performance for use in respiratory protection mask filters

Background and Aim: Electrospun nanofibers can be used to produce filter media in personal protective equipment for the military. The present study aimed to optimize the electrospinning process used to create polyurethane nanofiber substrates and compare the optimum substrate filtration performance with a typical commercial substrate used in the structure of N95 respirators. Methods: In this ex...

متن کامل

Determination of hexamethylene-based isocyanates in spray-painting operations. Part 1. Evaluation of a polyurethane foam sponge sampler.

A polyurethane foam (PUF) sponge was mounted in a cassette sampler and evaluated as a sorbent for the collection of hexamethylene diisocyanate (HDI) monomer and HDI-based oligomers. Recovery studies indicated 112 +/- 34% average recovery of HDI monomer and 92 +/- 9% and 97 +/- 25% average recovery of HDI-based oligomers when using impregnated PUF sponges. The PUF sponge was also evaluated durin...

متن کامل

Sampling gaseous oxidation products of aromatic compounds in gas/particle separation systems.

In this study we performed a direct comparison between two different ambient air samplers to characterize their performance in sampling oxidized gaseous organic compounds, known as oxidation products of aromatics. We investigated compounds with a variety of functional groups and vapor pressures. A polyurethane foam (PUF) adsorbent and an annular diffusion denuder sampler were operated along wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Aerosol science and technology : the journal of the American Association for Aerosol Research

دوره 50 5  شماره 

صفحات  -

تاریخ انتشار 2016