Effect of oxygen and temperature on the potassium efflux of irradiated, stored red blood cells.
نویسندگان
چکیده
Gamma irradiation of blood is performed to prevent transfusion-associated graft-versus-host disease and can result in an accelerated efflux of intracellular potassium (K+). The oxygen content of the blood and the temperature at which the irradiation is carried out are two variables reported to affect this shift; they were investigated in two separate studies. Study A-Four units of AS-5 red blood cells were each split equally into four transfer bags. One set of transfer bags was stored at 4 degrees C for 42 days (Control), the second set (IRR) was irradiated and stored. The third and fourth groups were oxygenated; the third set (+O2) was placed at 4 degrees C. The fourth set (IRR+O2) was irradiated, then stored. Supernatant K+ and hemoglobin increased in the IRR + O2 group over IRR and Control, +O2 did not rise compared to Control. Study B-Six units of CPDA-1 whole blood were each equally separated into four transfer bags. The first set of bags was placed at 4 degrees C, the second set was irradiated and then stored (IRR). The third group of bags was irradiated and given an 8-hour 22 degrees C incubation prior to storage at 4 degrees C (IRR-22). The fourth set was irradiated, placed at 37 degrees C for 2 hours, then stored. Supernatant K+ was lower during the first 7 days of storage for the IRR-22 and IRR-37 groups compared to IRR, but these increased to IRR levels by day 35. Irradiation of blood products results in an accelerated K+ shift that can be exacerbated by the presence of oxygen. The injury can be partially and temporarily corrected by a post-irradiation incubation at 22 degrees C or 37 degrees C.
منابع مشابه
The Alterations of Plasma Iipid Peroxidation and erythrocyte Superoxide Dismutase and Glutathione Peroxidase Enzyme Activities During Storage of Blood
Abstract Background and objective: Exposure of red blood cells to oxygen radicals can induce Lipid proxidation, hemoglobin damage and hemolysis of erythrocyte .The present study was designed to determine the alteration of plasma lipid peroxidation and erythrocyte Superoxide Dismutase and Glutathione Peroxidase enzyme activities in stored blood and to find out the quantitative alterations and th...
متن کاملRed blood cells storage lesion: the effect of blood donation time on biochemical parameters
Abstract Background and Objectives There is a circadian rhythm and diurnal variation in the redox capacity in blood plasma and there is a decrease in antioxidant capacity (TAC) during the RBCs storage in blood banking. So it is possible that donated blood, based on donation time, has a different antioxidant capacity and as a result a different biochemical response during storage. This study at...
متن کاملThe effect of metal chelators on lipid peroxidation in irradiated erythrocytes.
Prophylactic irradiation of blood and blood components is accepted practice in order to prevent graft-versus-host disease from infused lymphocytes. Irradiation, however, results in increased red cell potassium (K+) loss, along with other possible effects that may affect red cell function and viability. Lipid peroxidation (LP), a process initiated by the production of oxygen free radicals, is in...
متن کاملEffect of low dose X-ray on membrane fluidity of thalassemic red blood cells
Background: Chest X-ray is one of the examinations required for an annual health checkup. The interaction of radiation to the medium produces free radicals, which consequently causes biological changes either structural or properties of the cells. Whether the radiation from Chest X-ray upright technique affects the plasma membrane fluidity of thalassemic red blood cells (RBCs) is still unclear....
متن کاملDetermination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays
Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of clinical and laboratory science
دوره 24 4 شماره
صفحات -
تاریخ انتشار 1994