Comparison of Body Composition Measurements Using a New Caliper, Two Established Calipers, Hydrostatic Weighing, and BodPod

نویسندگان

  • ERIN E. TALBERT
  • MICHAEL G. FLYNN
  • JEFFREY W. BELL
  • ANDRES E. CARRILLO
  • MARQUITA D. DILL
  • CHRISTIANIA N. CHRISTENSEN
  • COLLEEN M. THOMPSON
چکیده

PURPOSES (1) To compare the Lafayette Instruments (LI) skinfold caliper to the Lange (L) and Harpenden (H) calipers using a diverse subject population. (2) To determine the validity of the LI caliper in a subset of subjects by comparing body compositions from skinfold thicknesses to those measured by hydrostatic weighing (HW) and air displacement plethysmography (ADP). (3) To compare measurements obtained by experienced (EX) and inexperienced (IX) technicians using all three calipers. METHODS Skinfold measurements were performed by both EX and IX technicians using three different calipers on 21 younger (21.2 ± 1.5 yrs) and 20 older (59.2 ± 4 yrs) subjects. Body compositions were calculated using the Jackson-Pollock seven-site and three-site formulas. HW and ADP tests were performed on a subset of subjects (10 younger, 10 older). RESULTS No significant differences existed between LI and L or H when measurements were made by EX. Further, the LI-EX measurements were highly correlated to both H-EX and L-EX. No significant differences existed in the subgroup between LI-EX and HW or ADP. Skinfold determinations made by EX and IX were similar. CONCLUSIONS Similar body compositions determined using LI, H, and L suggest that LI determines body composition as effectively as H and L. High correlations between the three calipers support this notion. Similar results between LI and HW/ADP subgroup suggest that the LI caliper may be a valid method of measuring body composition. Overall, performance by IX was similar to EX and suggests similar ease of use for all three calipers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anthropometric measurements and body composition of selected national athletes.

This study was conducted to determine the anthropometric measurements and body composition of selected national athletes. A total of 84 male athletes from 10 different types of sports and 24 female athletes from 5 types of sports were studied. The height and body weight of subjects were measured using the SEGA weighing balance with height attachment. Skinfold thickness measurements were taken u...

متن کامل

Horizontal Corneal White to White Diameter Measurements Using Calipers and IOLMaster

Purpose: To determine if the mean horizontal white-towhite (WTW) corneal diameter, measured intraoperatively with calipers, of a population of cataract surgery patients differs from the currently accepted normal WTW range of greater than 11.0 and less than 13.0 mm. In addition, we compared manual caliper measurements with those with IOLMaster. Setting: Cincinnati Eye Institute, Cincinnati OH. D...

متن کامل

Inter-Device Reliability of the BodPod for Clinical and Research Use A Senior Honors Thesis Presented in Partial Fulfillment of the Requirements for graduation with distinction in Human Nutrition, College of Education and Human Ecology

Air-displacement plethysmography (ADP) by the BodPod device is an increasingly popular instrument for determining body composition for both clinical and research applications. Despite previous studies, the reliability of ADP devices remains controversial and few studies testing inter-laboratory measurements exist. At our institution, we have the unique opportunity to have three BodPod devices l...

متن کامل

Comprehensive evaluation of selected methods for assessing human body composition.

The present study investigated the validity, reliability, objectivity, and practicability of methods with skinfold caliper (SF), ultrasound (US), bioelectrical impedance (BI), and sulfur hexafluoride (SHD) using identical subjects, and evaluated comprehensive usefulness by comparing selected methods or equations. In examining validity, underwater weighing (UW) was employed to obtain the criteri...

متن کامل

Measurement of fat thickness in man: a comparison of ultrasound, Harpenden calipers and electrical conductivity.

Indirect estimation of total body fat has been employed increasingly in recent years in an attempt to assess various aspects of body composition. In the most widely used method skinfold thickness is estimated by means of Harpenden calipers (Edwards, Hammond, Healey, Tanner & Whitehouse, 1955; Fletcher, 1962); these require a certain amount of practice in use. Since the instrument measures a ski...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2009