Optimizing everolimus exposure when combined with calcineurin inhibitors in solid organ transplantation.

نویسندگان

  • Teun van Gelder
  • Lutz Fischer
  • Fuad Shihab
  • Maria Shipkova
چکیده

The mammalian target of rapamycin (mTOR) inhibitor everolimus is a narrow therapeutic index drug for which optimal exposure levels are essential. The consistent pharmacokinetic profile of everolimus allows trough concentration (C0) measurement to be an appropriate and reliable index for therapeutic drug monitoring (TDM). Exposure-response analyses of data from early fixed-dose trials demonstrated that rates of biopsy-proven acute rejection (BPAR) are significantly higher if everolimus C0 declines below 3 ng/mL, an observation confirmed in subsequent concentration-controlled trials. Evidence for the most favorable upper limit is less clear but with reduced-exposure calcineurin inhibitor (CNI) therapy, an upper limit of 8 ng/mL appears to balance efficacy and safety outcomes. The recommended C0 range is 3-8 ng/mL in kidney, liver and heart transplantation patients, based on LC-MS/MS monitoring in whole blood. Randomized clinical trials based on this target range have demonstrated rates of BPAR comparable to a regimen of mycophenolic acid with standard-exposure CNI. Everolimus exhibits moderate intrapatient pharmacokinetic variability, and it can be challenging to maintain stable concentrations within target range in some individuals. Many factors can influence everolimus exposure for a given dose, including hepatic function, activity of the drug efflux pump P-glycoprotein, the rate of everolimus metabolism, drug-drug interactions (predominantly with CYP3A4 and P-glycoprotein inhibitors, including cyclosporine), intake of fatty food, and patient adherence to the prescribed regimen. Trough concentration levels should be monitored 4-5days after the first dose and after any change in everolimus dose, with additional monitoring in response to any change in concomitant medication or other clinical circumstances which could alter everolimus exposure. Although LC-MS/MS is the gold standard for everolimus monitoring, various immunoassays are widely used due to their relative simplicity and lower cost, and results can show considerable discrepancies with reference methods due to issues such as interassay variability and cross-reactivity. Method standardization will be important in the future to improve the consistency and reproducibility of results between centers. In conclusion, based on an extensive program of clinical trials, the optimal exposure range for everolimus in combination with reduced-exposure CNI therapy has been established and can be achieved in most transplant recipients through careful, planned TDM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oedema, solid organ transplantation and mammalian target of rapamycin inhibitor/proliferation signal inhibitors (mTOR-I/PSIs)

Mammalian target of rapamycin inhibitor (mTOR-I)/proliferation signal inhibitors (PSI) including sirolimus and everolimus represent a new class of drugs increasingly used in solid-organ transplantation as alternatives to calcineurin inhibitors for patients with renal dysfunction, transplant coronary arterial vasculopathy or malignancy. The most frequently occurring mTOR-I/PSI-related adverse ev...

متن کامل

Mammalian Target of Rapamycin Inhibitors and Nephrotoxicity: Fact or Fiction.

Mammalian target of rapamycin inhibitors, such as rapamycin and more recently everolimus, have substituted calcineurin inhibitors in many minimization strategies. Despite their acclaimed renal safety profile, several lines of evidence are emerging on their potential nephrotoxic effect. Predisposing conditions for nephrotoxicity involve a complex interplay between several environmental and genet...

متن کامل

Population pharmacokinetics and pharmacogenetics of everolimus in renal transplant patients.

BACKGROUND AND OBJECTIVE Everolimus is a novel macrolide immunosuppressant used in the prevention of acute and chronic rejection of solid organ transplants. Everolimus is being actively investigated worldwide as a non-nephrotoxic alternative for calcineurin inhibitors. Its highly variable pharmacokinetics and narrow therapeutic window make it difficult to maintain an adequate exposure to preven...

متن کامل

Everolimus and Malignancy after Solid Organ Transplantation: A Clinical Update

Malignancy after solid organ transplantation remains a major cause of posttransplant mortality. The mammalian target of rapamycin (mTOR) inhibitor class of immunosuppressants exerts various antioncogenic effects, and the mTOR inhibitor everolimus is licensed for the treatment of several solid cancers. In kidney transplantation, evidence from registry studies indicates a lower rate of de novo ma...

متن کامل

Everolimus in Heart Transplantation: An Update

The evidence base relating to the use of everolimus in heart transplantation has expanded considerably in recent years, providing clinically relevant information regarding its use in clinical practice. Unless there are special considerations to take into account, all de novo heart transplant patients can be regarded as potential candidates for immunosuppression with everolimus and reduced-expos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transplantation reviews

دوره 31 3  شماره 

صفحات  -

تاریخ انتشار 2017