Use of an apical suctioning device for placement of a posterior epicardial defibrillator patch: a case report.

نویسندگان

  • Fotios A Mitropoulos
  • Jonah Odim
  • Hillel Laks
چکیده

We report a case of a 43-year-old man with dilated cardiomyopathy and intractable ventricular tachycardias who did not respond to percutaneous implantable cardioverter defibrillator therapy and required implantation of epicardial patches. An apical suctioning device was used to retract the apex of the heart outside the mediastinal domain. The device provided excellent exposure and hemodynamic stability to safely implant the posterior epicardial patch.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erosion of the left ventricle by the epicardial patch of an automatic implantable cardioverter defibrillator.

A 56 year old man with an implantable cardioverter defibrillator was admitted with chest pain and collapse. Erosion of the left ventricle by an epicardial patch was confirmed by thoracotomy, but surgical repair was impossible. This rare complication should be considered in patients with a history of cardioverter defibrillators implanted by thoracotomy.

متن کامل

Fracture of the subcutaneous patch electrode in a patient with an implanted cardioverter-defibrillator.

There are more than 20 years of experience with implantation of defibrillator devices in humans and the procedure is an important therapeutic option for patients at high risk of life-threatening ventricular arrhythmias. The incidence of new defibrillator implantation has gradually increased, being used even in children, (1) although pediatric use is associated with several complications, especi...

متن کامل

Effect of epicardial patch electrodes on transthoracic defibrillation.

To improve survival rates in patients undergoing surgical ablative procedures for malignant ventricular tachycardia (VT), a frequent practice is to implant epicardial patch electrodes at the time of map-guided surgery. After operation, patients with inducible VT often receive an automatic internal cardioverter/defibrillator (AICD) implant, whereas patients with noninducible VT usually do not. I...

متن کامل

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The heart surgery forum

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 2006