Relative biological effectiveness of the 235 MeV proton beams at the National Cancer Center Hospital East.
نویسندگان
چکیده
A therapy-dedicated cyclotron was installed in the National Cancer Center Hospital East (NCCHE) at Kashiwa in 1997. Prior to the start of clinical use, we investigated the biological effectiveness of therapeutic proton beams for cell lethality. The proton beams accelerated up to 235 MeV were horizontally extracted from the cyclotron, and scattered by a bar-ridge filter to produce a Spread-Out-Bragg-Peak (SOBP) of 10-cm width. The biological systems used here were mouse intestinal crypt cells and three in vitro cell lines, including SCC61 human squamous cell carcinoma, NB1RGB human fibroblasts and V79 Chinese hamster cells. The dose responses after irradiation at either the entrance plateau or the middle portion of SOBP were compared with those after linac 6 MV X-ray irradiation. The fit of a linear quadratic model to survival curves showed that proton irradiation increased the alpha value of SCC61 and the beta value of V79 cells with a least change for alpha/beta ratio of NB1RGB cells. The isoeffect dose that reduces either cell survivals to 10% or mouse jejunum crypts to 10 per circumference was termed D10. The relative biological effectiveness (RBE) of protons obtained by comparing the D10 values between protons and X-rays ranged from 0.9 to 1.2. The depth distribution of cell lethality was measured by replating V79 cells after irradiation from a "cell stack chamber" that received a single dose of 7 Gy at the middle position of SOBP. The thus-obtained cell survivals at various depths coincided well with the estimated survivals, but tended to decrease at the distal end of SOBP. We conclude that an RBE of 1.1 would be appropriate for 235 MeV proton beams at the NCCHE.
منابع مشابه
Analysis of Relative Biological Effectiveness of Proton Beams and Iso-effective Dose Profiles Using Geant4
Background: The assessment of RBE quantity in the treatment of cancer tumors with proton beams in treatment planning systems (TPS) is of high significance. Given the significance of the issue and the studies conducted in the literature, this quantity is fixed and is taken as equal to 1.1.Objective: The main objective of this study was to assess RBE quantity of proton beams and their variations ...
متن کاملDifference in the relative biological effectiveness and DNA damage repair processes in response to proton beam therapy according to the positions of the spread out Bragg peak
BACKGROUND Cellular responses to proton beam irradiation are not yet clearly understood, especially differences in the relative biological effectiveness (RBE) of high-energy proton beams depending on the position on the Spread-Out Bragg Peak (SOBP). Towards this end, we investigated the differences in the biological effect of a high-energy proton beam on the target cells placed at different pos...
متن کاملEvaluation of variable relative biological effectiveness and the creation of homogenous biological dose in the tumor region in helium ion radiation to the V79 cell line
In radiation therapy, ions heavier than proton have more biological advantages than a proton beam. Recently, ion helium has been considered due to high linear energy transfer (LET) to the medium and a higher relative biological effect (RBE). To design the spread-out Bragg peak (SOBP) of biological dose for radiation with any type of ion, we need exact values of RBE, which is dependent to dose, ...
متن کاملRelative biological effectiveness of therapeutic proton beams for HSG cells at Japanese proton therapy facilities
We investigated the relative biological effectiveness (RBE) of therapeutic proton beams at six proton facilities in Japan with respect to cell lethality of HSG cells. The RBE of treatments could be determined from experimental data. For this purpose, we used a cell survival assay to compare the cell-killing efficiency of proton beams. Among the five linear accelerator (LINAC) X-ray machines at ...
متن کاملEnhanced radiobiological effects at the distal end of a clinical proton beam: in vitro study
In the clinic, the relative biological effectiveness (RBE) value of 1.1 has usually been used in relation to the whole depth of the spread-out Bragg-peak (SOBP) of proton beams. The aim of this study was to confirm the actual biological effect in the SOBP at the very distal end of clinical proton beams using an in vitro cell system. A human salivary gland tumor cell line, HSG, was irradiated wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of radiation research
دوره 42 1 شماره
صفحات -
تاریخ انتشار 2001