An x-ray diffraction study of corneal structure in mimecan-deficient mice.

نویسندگان

  • Nicola Beecher
  • Connie Carlson
  • Bryan R Allen
  • Rogers Kipchumba
  • Gary W Conrad
  • Keith M Meek
  • Andrew J Quantock
چکیده

PURPOSE Keratan sulfate proteoglycans (KSPGs) in the corneal stroma are believed to influence collagen fibrillar arrangement. This study was performed to investigate the fibrillar architecture of the corneal stroma in mice homozygous for a null mutation in the corneal KSPG, mimecan. METHODS Wild-type (n = 9) and mimecan-deficient (n = 10) mouse corneas were investigated by low-angle synchrotron x-ray diffraction to establish the average collagen fibrillar spacing, average collagen fibril diameter, and level of fibrillar organization in the stromal array. RESULTS The mean collagen fibril diameter in the corneas of mimecan-null mice, as an average throughout the whole thickness of the tissue, was not appreciably different from normal (35.6 +/- 1.1 nm vs. 35.9 +/- 1.0 nm). Average center-to-center collagen fibrillar spacing in the mutant corneas measured 52.6 +/- 2.6 nm, similar to the 53.3 +/- 4.0 nm found in wild-type mice. The degree of local order in the collagen fibrillar array, as indicated by the height-width (H:W) ratio of the background-subtracted interfibrillar x-ray reflection, was also not significantly changed in mimecan-null corneas (23.4 +/- 5.6), when compared with the corneas of wild-types (28.2 +/- 4.8). CONCLUSIONS On average, throughout the whole depth of the corneal stroma, collagen fibrils in mimecan-null mice, unlike collagen fibrils in lumican-null mice and keratocan-null mice, are of a normal diameter and are normally spaced and arranged. This indicates that, compared with lumican and keratocan, mimecan has a lesser role in the control of stromal architecture in mouse cornea.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mimecan/osteoglycin-deficient mice have collagen fibril abnormalities.

PURPOSE To study the role of mimecan, a member of the small leucine-rich proteoglycans (SLRPs) gene family and one of the major components of the cornea and other connective tissues, mice that lack a functional mimecan gene were generated and characterized. METHODS Mimecan-deficient mice were generated by gene-targeting using standard techniques. Mice were genotyped by Southern blot analysis....

متن کامل

An x-ray diffraction investigation of corneal structure in lumican-deficient mice.

PURPOSE The corneas of mice homozygous for a null mutation in lumican, a keratan sulfate-containing proteoglycan, are not as clear as normal. In the present study, mutant corneas were examined by synchrotron x-ray diffraction to see what structural changes might lie behind the loss of transparency. METHODS X-ray diffraction patterns were obtained from the corneas of 6-month-old and 2-month-ol...

متن کامل

Synthesis of BiVO4 nanoparticles by the co-precipitation method and study the crystal structure, optical and photocatalytic properties of them

In this paper, the bismuth vanadate (BiVO4) nanoparticles were synthesized at 600 °C calcination temperature by co-precipitation method. To study the crystal structure, morphology, optical and photocatalytic properties of the samples, the X-ray diffraction analysis, field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, Fourier-transform infrared spectroscopy and ult...

متن کامل

Neonatal development of the corneal stroma in wild-type and lumican-null mice.

PURPOSE Between days 8 and 14 of neonatal development, the corneal stroma of the mouse undergoes critical changes in tissue thickness, cell density, and light scattering. The authors investigate the stromal matrix structure in wild-type and lumican-deficient corneas in this developmental phase. METHODS Wild-type (n = 44) and lumican-deficient (n = 42) mouse corneas at neonatal days 8, 10, 12,...

متن کامل

Surface Hardness Measurment and Microstructural Characterisation of Steel by X-Ray Diffraction Profile Analysis

An X-ray diffraction line will broaden considerably when steels change into martensitic structure on quenching. The results presented in this paper show that X-ray diffraction technique can be employed for a rapid and nondestructive measurement of hardness of hardened steel. Measurement on various quenched and tempered steels showed that the breadth of its diffraction peak increased with increa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 46 11  شماره 

صفحات  -

تاریخ انتشار 2005