Low-voltage electric-discharge biolistic device.
نویسندگان
چکیده
dilution is limited primarily in its sensitivity. However, this is of concern only if very small numbers of organisms are suspected in a particular specimen, because the lower limits of detection for a 10-μL aliquot of undiluted material would be approximately 100 cfu/mL. There exists the possibility of crossing of paths as the plates are tilted. We experienced this problem only: (i) on media that were either excessively dry or had gross irregularities on their surfaces or (ii) when more than 6 samples were placed on a single 100× 15-mm plate. Use of media with a smooth surface and adequate spacing of samples minimizes erroneous track migration and mixing. Since detergents are often used for tissue homogenization (i.e., phagocytosis assays), we tested samples containing 10% (vol/vol) Triton X-100 and observed no interference with proper track formation (data not shown). In conclusion, bacterial enumeration by track dilution should prove a simple and reproducible tool, applicable to any number of experimental systems including bacterial growth kinetic studies and time-kill determinations. Although not specifically tested in this study, track dilution may prove useful for rapid enumeration of yeasts as well.
منابع مشابه
Synthesis of Zinc/Zinc Oxide Nanoparticles by Electric Discharge Method in Distilled-Water and Argon-Gas Environments
Zinc/zinc oxide nanoparticles are used in an increasing number of medical and industrial applications due to their attractive physical, chemical and antibacterial properties. Therefore, achieving a simple and beneficial way to produce them is an important aspect. In this study, zinc/zinc oxide nanopowders were synthesized by fast electric discharges between two electrodes of (a) a spark device ...
متن کاملطراحی و ساخت دستگاه اندازه گیری شدت میدان های الکتریکی و مغناطیسی به منظور ارزیابی سلامت شاغلین و مردمِ در معرض این میدان ها
In the extremely low frequency range (3 to 300 Hz), the intensities of electric and magnetic fields increase with increasing voltage and current. If the intensities of electric and magnetic fields are high compared with standard exposure limits, they can have harmful effects on human health. In the vicinity of power lines and high voltage power stations, the intensities of these fields are usua...
متن کاملElectric Insulation Detection Method for High-voltage Insulators
The principle of partial discharge detection is that through partial bridged discharge under high voltage electric field, it detects the inner air-filled cavity of high-voltage insulators. And it is a nondestructive detection method based on discharge magnitude to judge the insulation quality. The detecting system that adopts the partial discharge detection is more rigorous than testing system ...
متن کاملExperimental Study of Low-Pressure Nitrogen Dielectric Barrier Discharge
The electrical and spectral characteristics of a dielectric barrier discharge (DBD) are experimentally investigated in a sealed off coaxial cylinder filled with nitrogen at a pressure of 10 mbar. The discharge is a transient diffused glow at low frequency alternating voltage (60 Hz) and changes to a filamentary mode at high frequency alternating voltage (35 kHz). In case of pulsed voltage, the ...
متن کاملLow-Pass Filter for HV Partial Discharge Testing
The most common cause of high voltage electric machine malfunction is an electrical failure of the insulation system due to extreme partial discharges activity. The paper discusses the methodology for the construction of a low-pass high voltage filter for partial discharge measurement. It focuses mainly on the shape optimization, using an analytical approach with subsequent verification using t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BioTechniques
دوره 23 4 شماره
صفحات -
تاریخ انتشار 1997