Structure and elasticity of single-crystal (Mg,Fe)O and a new method of generating shear waves for gigahertz ultrasonic interferometry

نویسندگان

  • Steven D. Jacobsen
  • Hans-J. Reichmann
  • Hartmut A. Spetzler
  • Stephen J. Mackwell
  • Joseph R. Smyth
  • Ross J. Angel
  • Catherine A. McCammon
چکیده

[1] Knowledge of the elastic properties and crystal chemistry of dense oxide structures plays an important role in interpreting the composition and mineralogy of planetary interiors. We report the effects of (Mg,Fe) substitution and nonstoichiometry due to Fe on the crystal structure, elastic constants (cij) and moduli (K0T, K0S, G0) of (Mg,Fe)O utilizing single-crystal X-ray diffraction and gigahertz ultrasonic interferometry with a new method of generating high-frequency shear waves. The new acoustic technique features a P-to-S conversion by internal reflection on the oriented facet of a single-crystal MgO buffer rod. In addition to periclase (MgO) and wüstite (Fe0.95O), we investigated Fe-bearing (Mg,Fe)O single crystals prepared by interdiffusion having Fe/( Fe + Mg) = 0.06, 015, 0.24, 0.27, 0.37, 0.53, 0.56, 0.75, and 0.79, with ferric iron contents ranging from 1 to 12% of the total Fe. The elastic constants (c11, c12, c44) are determined from compressional and shear wave velocities in the [100] and [111] propagation directions in the range of 0.5–1.2 GHz. The c11 and c44 elastic constants soften from periclase to wüstite, whereas the c12 elastic constant increases. The rate of change in the elastic constants with composition (@cij/@x) is greatest between MgO and (Mg,Fe)O with 25 mol % FeO implying that substitution of Fe into periclase has a greater effect on the elastic properties than adding Mg to wüstite. The elastic anisotropy of (Mg,Fe)O has rather unusual behavior, being essentially constant for the range 0–25 mol % FeO but then decreases linearly with Fe content such that wüstite is elastically isotropic. The elastic properties of (Mg,Fe)O having similar total Fe but varying Fe contents are identical within uncertainty. The isothermal compressibility of samples with Fe/( Fe + Mg) = 0.27, 0.56, and 0.75 is determined by single-crystal X-ray diffraction in a diamond anvil cell to 9 GPa. For these samples, K0T = 158.4(4), 155.8(9), and 151.3(6) GPa with @KT/@P = 5.5(1), 5.5(1), and 5.6(2), respectively (where values in parentheses indicate standard deviations). The deviation of @KT/@P from 4.0 corresponds to a difference in calculated density of about one percent for ferropericlase (Mg0.8Fe0.2)O at 30 GPa from the value predicted by second-order truncation of the BirchMurnaghan equation of state.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gigahertz ultrasonic interferometry at high P and T : new tools for obtaining a thermodynamic equation of state

A new method of generating shear waves with near-optical wavelength has been developed for gigahertz ultrasonic interferometry. The new acoustic technique features a P-to-S conversion upon reflection inside an MgO buffer rod, and is used first to determine the full set of ambient P–T elastic constants (ci j ) of magnesiowüstite—(Mg, Fe)O. In addition, P-wave travel times have been measured in o...

متن کامل

Shear waves in the diamond-anvil cell reveal pressure-induced instability in (Mg,Fe)O.

The emerging picture of Earth's deep interior from seismic tomography indicates more complexity than previously thought. The presence of lateral anisotropy and heterogeneity in Earth's mantle highlights the need for fully anisotropic elasticity data from mineral physics. A breakthrough in high-frequency (gigahertz) ultrasound has resulted in transmission of pure-mode elastic shear waves into a ...

متن کامل

Modern techniques in measuring elasticity of Earth materials at high pressure and high temperature using ultrasonic interferometry in conjunction with synchrotron X-radiation in multi-anvil apparatus

In the past 6 years, state-of-the-art techniques have been developed for the studies of elastic properties of polycrystalline and single-crystal materials using simultaneous ultrasonic and X-ray diffraction techniques at high pressures and temperatures in multi-anvil apparatus. The capability of these techniques is illustrated using recent data for mantle phases such as forsterite, wadsleyite, ...

متن کامل

Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics.

Shear wave elasticity imaging (SWEI) is a new approach to imaging and characterizing tissue structures based on the use of shear acoustic waves remotely induced by the radiation force of a focused ultrasonic beam. SWEI provides the physician with a virtual "finger" to probe the elasticity of the internal regions of the body. In SWEI, compared to other approaches in elasticity imaging, the induc...

متن کامل

Synthesis, Characterization, and Crystal Structure Determination of a New Copper(II) Complex: [H2en][Cu(pydc)2].2H2O

The new complex of [H2en][Cu(pydc)2].2H2O (1) (where H2en and pydc are ethylenediammonium and 2,6-pyridinedicarboxylate, respectively) was synthesized by the reaction of a mixture of ethylenediamine (en) and 2,6-pyridinedicarboxylic acid (H2pydc) in a mixture of CH3OH/H2O as solvent. This complex was fully characterized by elemental analysis, IR, UV–Vis spectroscopy as well as single-crystal X-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002