Electrophoresis on cellulose acetate and chromatography on DEAE-sephadex A-50 compared in the estimation of creatine kinase isoenzymes.
نویسندگان
چکیده
We have compared two methods for separating the isoenzymes of creatine kinase in serum and measuring their activity: chromatography on diethylaminoethyl-Sephadex A-50, with both continuous and discontinuous gradient elution, and electrophoresis on cellulose acetate. Results by continuous and discontinuous gradient elution correlated well both for tissue extracts and sera. Electrophoresis on cellulose acetate is evidently less sensitive than the chromatographic method for detecting and measuring low activities of the isoenzyme designated MB. We describe how the isoenzymes may be separated by discontinuous gradient elution from microcolumns of the Sephadex and their activity rapidly quantitated by the Rosalki method [J. Lab. Clin. Med. 69, 696 (1967)], with a centrifugal analyzer.
منابع مشابه
Creatine kinase isoenzyme patterns in human tissue obtained at surgery.
Chromatography on DEAE-Sephadex A-50 was applied to study the quantitative distribution of creatine kinase isoenzymes in extracts of human tissue obtained during surgery. The results are compared with those determined by an immunological method [Clin. Chim. Acta 58, 223 (1975)]. Conflicting results for some organs as reported by the two methods are probably attributable to postmortem autolysis.
متن کاملSeparation of serum creatine kinase isoenzymes by ion-exchange column chromatography.
We describe a practical, technically convenient DEAE-Sephadex chromatographic column and a three-fraction salt-gradient elution procedure, with which serum creatine kinase activity is rapidly and quantitatively separated into the isoenzyme components with excellent analytical recovery of the total activity applied. The homogeneity of the isoenzyme fractions was demonstrated by electrophoresis a...
متن کاملCreatine kinase B-subunit activity in human sera: temporal aspects of its sensitivity after myocardial infarction.
We assessed the changes in sensitivity and specificity of creatine kinase (CK) isoenzymes at various times after acute myocardial infarction. CK-B was measured by an immunoinhibition technique. CK-MB was measured both by column chromatography on Sephadex DEAE A-50 and by electrophoresis on agarose gel. For CK-B, the sensitivity in detecting infarct varied from 11% in the first 8 h after onset o...
متن کاملHuman Placental
AMAcetyl-,-he,osanindases A andUwere purifled to homogeneityfromhuman placenta. 1n the imt'al step of purication, thfe enzymes were adsorbed on concanavalin ASepharose 4B and etuted from, the column with a-methyl D-mannoside. Subsequent purification steps includedc DEAE-cellulose column chromn-atography, QAE-Seph%adex Ediethyl-(2-hydroxypropyl)aminoethyl-Sephadex] column chromatography1 Sephade...
متن کاملIn Vitro Inhibition of Human Sperm Creatine Kinase by Nicotine, Cotinine and Cadmium, as a Mechanism in Smoker Men Infertility
Background Nicotine, cotinine and cadmium are harmful components of cigarettes that have an effect on human reproductive function. Although the effects of cigarette smoke on male reproductive function is characterized in several articles its mechanism of action is still unknown. In the present study, we investigate the effect of nicotine, cotinine and cadmium on human sperm creatine kinase acti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 21 3 شماره
صفحات -
تاریخ انتشار 1975