Unsuitability of evacuated tubes for monitoring heparin therapy by activated partial thromboplastin time.

نویسندگان

  • A D Heyns
  • D J van den Berg
  • P H Kleynhans
  • P W du Toit
چکیده

Activated partial thromboplastin times (APTT) for monitoring heparin therapy for venous thromboembolism tended to be inappropriately short if blood was collected in commercially available evacuated glass tubes. Five types of evacuated tubes marketed under the trade names Vacutainer and Venoject were examined. The APTT of heparinized blood collected in these tubes correlated poorly (r = 0.04 to 4 = 0.25) with that of blood samples from the same patients collected in plastic tubes. Most of the evacuated tube APTT were shorter than that of blood collected in plastic or siliconised glass tubes, but the results were unpredictable and varied from tube to tube and from batch to batch. This effect on heparin is apparently due to an unidentified substances which is eluted from the rubber stoppers of the tubes. Heparin control according to the APTT blood collected in these evacuated tubes is hazardous.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Siliconised Glass Tubes

Activated partial thromboplastin times (APTT) for monitoring heparin therapy for venous thromboembolism tended to be inappropriately short if blood was collected in commercially available evacuated glass tubes. Five types of evacuated tubes marketed under the trade names Vacutainer and Venoject were examined. The APTT of heparinised blood collected in these tubes correlated poorly (r = 004 to r...

متن کامل

Siliconised Glass Tubes

Activated partial thromboplastin times (APTT) for monitoring heparin therapy for venous thromboembolism tended to be inappropriately short if blood was collected in commercially available evacuated glass tubes. Five types of evacuated tubes marketed under the trade names Vacutainer and Venoject were examined. The APTT of heparinised blood collected in these tubes correlated poorly (r = 004 to r...

متن کامل

A new plastic collection tube made of polyethylene terephtalate is suitable for monitoring traditional anticoagulant therapy (oral anticoagulant, unfractionated heparin, and low molecular weight heparin).

To improve the safety of blood collection, plastic tubes have been developed but various interactions with the coagulation system and/or antithrombotic drugs were reported with the first generation of such tubes. The aim of this multicentre study was to compare hemostasis test results measured in evacuated plastic tubes made of polyethylene terephtalate (VenoSafe, Terumo Europe) and in siliconi...

متن کامل

بررسی مقایسه‌ای تاثیر 2 روش تجویز هپارین به صورت مداوم و متناوب بر روی زمان ترومبوپلاستین نسبی

Comparative Study of Continuous and Intermittent Administration of Heparin on APTT (Activated Partial Thromboplastin Time) I II *A. Adib, MD B. Fatourchi, MD Abstract There are many different doses and protocols of heparin injection for treatment or prevention of many thrombotic diseases. The present interventional experimental(Clinical trial) study was conducted to compare the effect of contin...

متن کامل

Heparin Resistance During and Post-Intravenous Nitroglycerin Infusion

      Nitroglycerin has been reported to reduce activated partial thromboplastin time (aPTT) values in patients treated with concurrent heparin and nitroglycerin. However, studies have yielded conflicting results. To determine whether intravenous nitroglycerin alters the anticoagulant effect of heparin, we prospectively evaluated twenty patients admitted for coronary angioplasty by measurin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 1981