EOS(®) biplanar X-ray imaging: concept, developments, benefits, and limitations.
نویسندگان
چکیده
PURPOSE In 1992, Georges Charpak invented a new type of X-ray detector, which in turn led to the development of the EOS(®) 2D/3D imaging system. This system takes simultaneous anteroposterior and lateral 2D images of the whole body and can be utilized to perform 3D reconstruction based on statistical models. The purpose of this review is to present the state of the art for this EOS(®) imaging technique, to report recent developments and advances in the technique, and to stress its benefits while also noting its limitations. METHODS The review was based on a thorough literature search on the subject as well as personal experience gained from many years of using the EOS(®) system. RESULTS While EOS(®) imaging could be proposed for many applications, it is most useful in relation to scoliosis and sagittal balance, due to its ability to take simultaneous orthogonal images while the patient is standing, to perform 3D reconstruction, and to determine various relationships among adjacent segments (cervical spine, pelvis, and lower limbs). The technique has also been validated for the study of pelvic and lower-limb deformity and pathology in adult and pediatric populations; in such a study it has the advantage of allowing the measurement of torsional deformity, which classically requires a CT scan. CONCLUSIONS The major advantages of EOS(®) are the relatively low dose of radiation (50-80 % less than conventional X-rays) that the patient receives and the possibility of obtaining a 3D reconstruction of the bones. However, this 3D reconstruction is not created automatically; a well-trained operator is required to generate it. The EOS(®) imaging technique has proven itself to be a very useful research and diagnostic tool.
منابع مشابه
EOS imaging versus current radiography: A health technology as-sessment study
Background: EOS is a 2D/3D muscle skeletal diagnostic imaging system. The device has been developed to produce a high quality 2D, full body radiographs in standing, sitting and squatting positions. Three dimensional images can be reconstructed via sterEOS software. This Health Technology Assessment study aimed to investigate efficacy, effectiveness and cost-effectiveness of new emerged EOS imag...
متن کاملEOS 2D/3D X-ray imaging system: a systematic review and economic evaluation.
BACKGROUND EOS is a biplane X-ray imaging system manufactured by EOS Imaging (formerly Biospace Med, Paris, France). It uses slot-scanning technology to produce a high-quality image with less irradiation than standard imaging techniques. OBJECTIVE To determine the clinical effectiveness and cost-effectiveness of EOS two-dimensional (2D)/three-dimensional (3D) X-ray imaging system for the eval...
متن کاملIdiopathic scoliosis in children and adolescents: assessment with a biplanar X-ray device
UNLABELLED Idiopathic scoliosis is one of the most common conditions encountered in paediatric practice. It is a three-dimensional (3D) spinal deformity. Conventional radiography is still the modality of choice for evaluation of children and adolescents with idiopathic scoliosis, but it requires repeat radiographs until skeletal maturity is reached and does not provide information about spinal ...
متن کاملAn Overview of Technological Developments in Medical Applications of X-Rays and Radioactivity
The years 1895 to 1898 were momentous for their impact on health and human well beings. First, Wilhelm Roentgen noted a glowing fluorescent screen, caused by invisible rays. This event subsequently led to the discovery of X-rays in 1895, and thus the birth of the “atomic ageâ€. Next Becquerel’s investigations of these mysterious rays led to his experiments with uranium salt crystals. He th...
متن کاملComparison of entrance skin dose in the hip region in the imaging of the lower extremity by CT scan and EOS
Introduction: Increasing in refer to computed tomography (CT-scan) imaging causes to increase in cumulative dose. Stereoradiography (EOS) is an X-ray imaging technology that, by eliminating scattering radiation, reduces patient's absorption dose and improves image quality. Materials and Methods: This cross-sectional study was carried out in a hosp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of children's orthopaedics
دوره 10 1 شماره
صفحات -
تاریخ انتشار 2016