In-phantom depth-dose measurements in mammography utilizing a Compton spectrometer

نویسندگان

  • Tania A. C. Furquim
  • Ricardo A. Terini
  • Silvio B. Herdade
چکیده

Mammography, using X-rays, is routinely utilized for screening of patients for prevention of breast cancer. Nevertheless, there is a small but significant risk of radiation induced carcinogenenesis associated with radiation exposure of the breast, being glandular tissue the most sensitive one among the tissues composing breast. Risk estimation in mammography may be determined by the mean absorbed dose in the glandular tissue, . It is impossible to measure directly. Conversion factors are used to derive from measurements of incident exposure or kerma in free air, which may be obtained by Monte Carlo calculations in mathematical breast models, or from depth-dose measurements in homogeneous breast phantoms. In this work, X-ray beams from two apparatuses have been used in connection with a BR-12 mammography phantom: a GE Senographe 700T clinical unit, Mo anode/Mo filter, and a Philips constant potential equipment, W anode/Mo filter. values have been determined by two procedures: (a) by measurement of the incident air kerma, using an ionization chamber, multiplied by conversion factors from the literature, determined by Monte Carlo calculations on the basis of breast models; (b) by obtaining the incident air kerma and the dose, in several depths in a BR-12 phantom, by means of X-ray energy spectra measured with a Compton spectrometer. In this spectrometer, the radiation scattered by a small cylindrical Lucite probe, located over or inside the phantom, is detected, at an angle of about 90 o with the direction of the primary beam, by a CdTe semiconductor detector. The air kerma and in-phantom depth-doses, in the X-ray primary beam, are obtained by utilizing the Klein-Nishina cross-section and parameters of the experimental setup. Depth-dose curves and results normalized for unit incident air kerma were obtained for both systems and are presented for 30 kV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of glandular dose in mammography in the presence of breast cyst using Monte Carlo simulation

Introduction: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. In this study, DgN is evaluated in the presence of breast cyst, which is a common disease among women and the influence of size, number and location of the cysts on the DgN is investigated. Materials and Meth...

متن کامل

The effect of electronic disequilibrium on the received dose by lung in small fields with photon beams: Measurements and Monte Carlo study

Background: Prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. Application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. To study the lung absorbed dose in radiotherapy with smal...

متن کامل

Optimization of 3D Planning Dosimetry in a Breast Phantom for the Match Region of Supraclavicular and Tangential Fields

Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...

متن کامل

Evaluation of depth dose characteristics of superficial X-rays machine using different kVp and applicators diameter

Background: Radiotherapy Treatment Planning requires different dosimetric quantities as input in order to calculate a desired dose distribution. This study has been focused to evaluate the depth dose characteristics of superficial X-rays being used for radiotherapy treatment. Materials and Methods: Computerized 3-D water phantom of multi-data system was used. The measurements were made...

متن کامل

Total skin electron therapy (TSET): Monte Carlo Simulation and implementation

Introduction: Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Operating procedures for total skin electron irradiation and its dosimetry vary in different radiation therapy centers in the world. In this article, validation of TSET techniq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008