Correlation between hemin content and the chemiluminescent luminol reaction with bacteria.
نویسندگان
چکیده
Protohemin and covalently bound hemin were determined in eight aerobic bacterial strains. A good correlation between protohemin content and luminol reactivity was found. The ratio of luminol reaction to protohemin for the eight investigated strains was essentially identical to that of pure protohemin, 0.7 X 10(16) mV/mol. Covalently bound hemin contributed to the chemiluminescence to a minor extent only (0.7 X 10(14) mV/mol, in accordance with earlier observations of the lower reactivity of cytochrome c and related compounds. A difference in reaction kinetics of the luminol reaction with covalently bound hemin (slower reaction than protohemin) and protohemin was observed in vivo as well as in vitro. The phenomenon could be used to differentiate between strains with different hemin composition.
منابع مشابه
Chemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System
A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...
متن کاملDetermination of iron-porphyrin-like complexes at nanomolar levels in seawater.
A new method for the non-specific determination of iron-porphyrin-like complexes in natural waters has been developed. It is based on the chemiluminescent oxidation of the luminol in the presence of dioxygen (O2) at pH 13. The method has been implemented in a FIA manifold that allowed the direct injection of seawater. The limit of detection is 0.11 nM of equivalent hemin (Fe-protoporphyrin IX)....
متن کاملChemiluminescent studies of t-butylhydroperoxide with phenyl hydrazine hydrochloride in the presence and absence of luminol
The chemiluminescence (CL) accompanying the oxidation of phenyl hydrazine with t-butylhydroperoxide in alkaline medium was studied in the presence and absence of luminol. The reaction occurring between phenyl hydrazine and alkaline (KOH) solution of aqueous tbutylhydroperoxide leads to the production of nitrogen gas with simultaneous emission of light (CL), which has been detected by PMT and re...
متن کاملCoFe2O4 magnetic nanoparticles as a peroxidase mimic mediated chemiluminescence for hydrogen peroxide and glucose.
This communication presents a new peroxidase mimic of CoFe(2)O(4) nanoparticles evaluated by the luminol-based chemiluminescent (CL) reaction. This offers a new method for evaluation and screening of the nanoparticles-based enzyme mimetics.
متن کاملAn electrochemiluminescent microRNA biosensor based on hybridization chain reaction coupled with hemin as the signal enhancer.
In this study, a new universal biosensor based on luminol anodic electrochemiluminescence (ECL) for the detection of microRNA-155 was constructed by using hydrogen peroxide (H2O2) as a co-reactant and hemin as a catalyzer for signal amplification. The bare glassy carbon electrode (GCE) was first electrodeposited with Au nanoparticles (AuNPs). Then, helper DNA, which was partly complementary wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 36 6 شماره
صفحات -
تاریخ انتشار 1978