Quadruple Disruption of the Superior Shoulder Suspensory Complex (SSSC) and Outcome after One Year of Conservative Treatment: A Case Report

نویسندگان

  • Felix Toft
  • Fabrizio Moro
چکیده

The Superior Shoulder Suspensory Complex (SSSC) comprises a bony and soft tissue ring including the clavicle, acromioclavicular (AC) joint, acromial process, glenoid fossa and process, coracoid process and coracoclavicular ligaments [1]. This complex is believed to have important biomechanical functions concerning shoulder stability and overall shoulder function, and connects the upper extremity via the clavicle with the axial skeleton [2]. Disruption of the SSSC at a single location due to a clavicle fracture, acromion fracture, or ACjoint dislocation with intact coracoclavicular (CC) ligaments, is a common injury often treated conservatively as the stability of the SSSC is still warranted, if no other indication for operative therapy exists. Double disruption of the SSSC is a rare injury thought to destabilize the construct, and therefore operative repair of one or both of the involved structures is recommended [3-8]. Triple and quadruple SSSC disruptions have been reported, although they are even rarer. They most often result from high energy trauma events, which are very often accompanied by associated injuries of the ribs, spine, nerves and head [9-18]. The more parts of the SSSC are injured, the greater the instability of the shoulder girdle. Thus, almost all of these injury types are treated surgically. We report on the radiological and functional outcome of a quadruple SSSC disruption, which was successfully treated in a conservative manner and followed up for one year posttrauma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unusual Medial-End Clavicle Fracture Combined with Double Disruption of the Superior Shoulder Suspensory Complex (SSSC) : A Case Report in Triathlon Athlete

INTRODUCTION Most published floating clavicle report a dislocation or fracture of one or both ends of the clavicle. CASE PRESENTATION We reported a new framework of this injury in a young triathlon athlete; medial-end displaced fracture with co-existent double disruption of the superior shoulder suspensory complex (SSSC) with the anterior shoulder arch wholly disconnected from the nearby stru...

متن کامل

3-D Printing Technique to Aid Surgical Planning in Treatment of Floating Shoulder Injury: A Case Report

The term ‘‘floating shoulder ’’ was introduced by Herscovici in 1992 [1], charactered by ipsilateral scapular neck and clavicular shaft fractures. The definition of ‘floating shoulder’’ has been criticized by many authors, and the widely accepted definition is a double disruption of the superior suspensory shoulder complex (SSSC) [2-5]. SSSC is a bony/soft tissue structure, playing important ro...

متن کامل

Surgical treatment of Ideberg type III glenoid fractures with associated superior shoulder suspensory complex injury.

Ideberg type III glenoid fractures with associated superior shoulder suspensory complex (SSSC) injuries are rare, and related treatments have not been reported in the literature. The purpose of this study was to evaluate the clinical outcomes of such injuries treated with open reduction and internal fixation (ORIF). Between July 2007 and April 2012, ten patients with Ideberg type III glenoid fr...

متن کامل

Corrective Osteotomy for Ipsilateral Distal Clavicular and Coracoid Malunions.

Malunion after double disruption injuries of the superior shoulder suspensory complex accompanied by shoulder pain and dysfunction has been reported infrequently. A 37-year-old man had a double disruption injury (fractures of the distal clavicle and the base of the coracoid process). Conservative treatment resulted in malunion. Twelve months after the injury, pain continued in the coracoclavicu...

متن کامل

Conservative management of superior vena cava injury due to hemodialysis catheter placement: A case report and literature review

We reported the case of a 78-year old woman with the inadvertent superior vena cava injury resulting from hemodialysis catheter placement. The catheter was placed through the left internal jugular vein. Hemodynamics were stable. The initial chest film illustrated an extraluminal catheter and mediastinal widening. The patient did not have hemothorax. Computed tomography venography also confirmed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016