Assessment of CT dose in X-ray CT polyacrylamide gel dosimetry
نویسندگان
چکیده
منابع مشابه
Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملInvestigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT
Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...
متن کاملBrachytherapy polymer gel dosimetry with xCT
ABSTRACTBackground: Polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. Research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. In the current work, we present our preliminary results of investigating capability of X-r...
متن کاملPolymer gel dosimetry using x-ray computed tomography: a feasibility study.
A new three-dimensional dosimetry technique using x-ray computed tomography (CT) to analyse polymer gels is proposed. The CT imaging is sensitive to radiation-induced density changes that occur within irradiated polyacrylamide gel (PAG). In this preliminary study, a CT imaging protocol is developed to optimize CT images of PAG; the response of PAG CT number to dose (N(CT)-dose response) and the...
متن کاملCT gel dosimetry technique: Comparison of a planned and measured 3D stereotactic dose volume
This study presents a 3D dose mapping of complex dose distributions using an x-ray computed tomography (CT) polymer gel dosimetry technique. Two polyacrylamide gels (PAGs) of identical composition were irradiated with the same four arc stereotactic treatment to maximum doses of 15 Gy (PAG1) and 8 Gy (PAG2). The PAGs were CT imaged using a previously defined protocol that involves image averagin...
متن کامل