Effects of pulse rate on threshold and dynamic range in Clarion cochlear-implant users.
نویسندگان
چکیده
The effects of pulse rate on absolute threshold ~THS!, maximum acceptable loudness ~MAL!, and dynamic range ~DR! were evaluated in 15 Clarion cochlear implant users. A wider range of pulse rates was assessed than in previous studies, and subjects with both standard and perimodiolar electrode arrays were tested. THS and MAL decreased with pulse rate, and DR increased with pulse rate, for pulse rates between 200 and 6500 pulses per second ~pps!. However, slopes of THS-vs-pulse rate and MAL-vs-pulse rate functions became shallower above 3250 pps. Subjects with standard electrode arrays had similar THSs as subjects with perimodiolar electrode arrays at all pulse rates. In contrast, subjects with standard arrays had significantly higher MALs and larger DRs than subjects with perimodiolar arrays, and these differences became larger with increasing pulse rate. © 2004 Acoustical Society of America. @DOI: 10.1121/1.1701895#
منابع مشابه
Effects of pulse rate and electrode array design on intensity discrimination in cochlear implant users.
The effects of pulse rate on intensity discrimination were evaluated in 14 subjects with Clarion C-I cochlear implants. Subjects had a standard [Clarion spiral electrode array (SPRL group)] or perimodiolar electrode array [Clarion HiFocus electrode array with electrode positioning system (HF+EPS group)]. Weber fractions for intensity discrimination [ Wf(dB)= 10 log deltaI/I] were evaluated at f...
متن کاملTimbral recognition and appraisal by adult cochlear implant users and normal-hearing adults.
The purpose of this study was to examine the appraisal and recognition of timbre (four different musical instruments) by recipients of Clarion cochlear implants (CIS strategy, 75- or 150-microsec pulse widths) and to compare their performance with that of normal-hearing listeners. Twenty-eight Clarion cochlear implant users and 41 normal-hearing listeners were asked to give a subjective assessm...
متن کاملSpeech dynamic range and its effect on cochlear implant performance.
This study examines optimal conversions of speech sounds to audible electric currents in cochlear-implant listeners. The speech dynamic range was measured for 20 consonants and 12 vowels spoken by five female and five male talkers. Even when the maximal root-mean-square (rms) level was normalized for all phoneme tokens, both broadband and narrow-band acoustic analyses showed an approximately 50...
متن کاملNeurophysiology of cochlear implant users II: comparison among speech perception, dynamic range, and physiological measures.
OBJECTIVE The overall objective of this study was to relate electrically evoked potentials recorded from different levels of the auditory pathway with behavioral measures obtained from adult cochlear implant subjects. The hypothesis was that adult recipients of cochlear implants who have open-set speech perception and those recipients with no open-set speech perception would differ in their neu...
متن کاملExamining the auditory nerve fiber response to high rate cochlear implant stimulation: chronic sensorineural hearing loss and facilitation.
Neural prostheses, such as cochlear and retinal implants, induce perceptual responses by electrically stimulating sensory nerves. These devices restore sensory system function by using patterned electrical stimuli to evoke neural responses. An understanding of their function requires knowledge of the nerves responses to relevant electrical stimuli as well as the likely effects of pathology on n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 115 5 Pt 1 شماره
صفحات -
تاریخ انتشار 2004