Experimental characterisation of CCD cameras for HREM at 300 kV

نویسندگان

  • Meyer
  • Kirkland
  • Dunin-Borkowski
  • Hutchison
چکیده

The modulation transfer function, noise transfer function and detection quantum efficiency of both 1k2 and 2k2 cameras attached to the same 300 kV FEGTEM have been measured. The results show that both the MTF and the DQE of the 2k2 camera are lower than for the 1k2 camera at frequencies above a third of the Nyquist limit. This lower per-pixel performance of the 2k2 camera is primarily a result of the use of a thicker phosphor scintillator. However, MTF and DQE of the 2k2 camera operated as an effective 1k2 camera by using 2 x 2 pixel binning are superior to the 1k2 camera in the medium spatial frequency range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Achievable resolution from images of biological specimens acquired from a 4k x 4k CCD camera in a 300-kV electron cryomicroscope.

Bacteriorhodopsin and epsilon 15 bacteriophage were used as biological test specimens to evaluate the potential structural resolution with images captured from a 4k x 4k charge-coupled device (CCD) camera in a 300-kV electron cryomicroscope. The phase residuals computed from the bacteriorhodopsin CCD images taken at 84,000x effective magnification averaged 15.7 degrees out to 5.8-A resolution r...

متن کامل

Experimental Study of Charging Efficiencies and Losses of Submicron Aerosol Particles in a Cylindrical Tri-Axial Charger

The object of the present work was to design, construct and evaluate a cylindrical tri-axial charger for charging of submicron aerosol particles by unipolar ions. The corona discharge characteristics, the intrinsic and extrinsic particle charging efficiencies, and the losses of aerosol particles were experimentally evaluated for particle diameters in the range between 50 nm and 500 nm under dif...

متن کامل

Defocusing Effect Studies in MTF of CCD Cameras Based on PSF Measuring Technique

Defocusing effects in modulation transfer function (MTF) measurement of charge coupled device (CCD) cameras is the main focus of current paper. We introduce measuring Point-spread function (PSF) in order to calculate the MTF and further more we will study the shape of MTF and its cut-off frequency by adjusting the lens focusing in different locations. A collimated white light LED by broadband s...

متن کامل

Off-Axial Aberration Correction using a B-COR for Lorentz and HREM Modes

A dedicated Hitachi HF3300C microscope, “I2TEM”, has recently been installed in CEMES. This microscope has been specially designed to carry on electron interferometry and in-situ TEM experiments. I2TEM is a 300 kV cold FEG microscope fitted with a multibrism set-up, two stages capability, a GIF quantum ER, a 4k X 4k camera and a Cs-corrector “B-COR” from CEOS. The first stage location within th...

متن کامل

Comparative Geometric Tests of Industrial and Scientific Ccd Cameras Using Plumb Line and Test Range Calibrations

Small format, medium resolution CCD cameras are at present widely used for industrial metrology applications. Large format, high resolution CCD cameras are principally used for scientific applications, but are slowly infiltrating photogrammetry and dramatically improving the object space accuracy achievable by close range measurement. The calibration of all types of CCD cameras is necessary in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultramicroscopy

دوره 85 1  شماره 

صفحات  -

تاریخ انتشار 2000