Respiratory mechanics with constant flow inspiration. A comparison of two measurement techniques.
نویسندگان
چکیده
Resperatory compliance and resistance were measured during positive pressure ventilation in anaesthtized, paralysed dogs. Airway pressures measured during constant-flow inspiration allowed the calculation of pulmonary and chest-wall resistances, and static and non-static compliances. Contiguous studies of dynamic compliance and resistance allowed comparison of the two techniques, and the level of agreement was reasonalble. Cconstant-flow inflation of the lungs allows a simple means of measuring respiratory mechanics, and should be valid for the observation of short-term changes in the apnoeic patient.
منابع مشابه
Comparing two different modes of mechanical ventilation by the least square fitting method: nava versus PSV
Introduction The Least Square Fitting (LSF) method is a statistical approach used for evaluating respiratory mechanics [1]. It allows measurement of respiratory mechanics continuously at the bedside, even in presence of flow limitation [23], without the need for constant inspiratory flow rate, endinspiratory hold and end-expiratory occlusion. These features allow the application of the LSF meth...
متن کاملEffects of inspiratory flow waveforms on arterial blood gases and respiratory mechanics after open heart surgery.
The clinical usefulness of inspiratory flow pattern manipulation during mechanical ventilation remains unclear. The aim of this study was to investigate the effects of different inspiratory flow waveforms, i.e. constant, sinusoidal and decelerating, on arterial blood gases and respiratory mechanics, in mechanically ventilated patients. Eight patients recovering after open heart surgery for valv...
متن کاملA method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow
Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...
متن کاملHumidification performance of two high-flow nasal cannula devices: a bench study.
INTRODUCTION Delivering heated and humidified medical gas at 20-60 L/min, high-flow nasal cannula (HFNC) creates low levels of PEEP and ameliorates respiratory mechanics. It has become a common therapy for patients with respiratory failure. However, independent measurement of heat and humidity during HFNC and comparison of HFNC devices are lacking. METHODS We evaluated 2 HFNC (Airvo 2 and Opt...
متن کاملA new ventilator for monitoring lung mechanics in small animals.
Researchers investigating the genetic component of various disease states rely increasingly on murine models. We have developed a ventilator to simplify respiratory research in small animals down to murine size. The new ventilator provides constant-flow inflation and tidal volume delivery independent of respiratory parameter changes. The inclusion of end-inspiratory and end-expiratory pauses si...