The gum elastic bougie eases tracheal intubation while applying cricoid pressure compared to a stylet.

نویسندگان

  • Takashi Noguchi
  • Kazunori Koga
  • Yousuke Shiga
  • Akio Shigematsu
چکیده

PURPOSE To compare the ease of tracheal intubation facilitated by the gum elastic bougie or the malleable stylet while applying cricoid pressure. METHODS Sixty American Society of Anesthesiologists I-III adult patients undergoing elective surgeries participated in this study. After induction of anesthesia with 2.5 mg x kg(-1) propofol and vecuronium 0.1 mg x kg(-1), the laryngeal view was assessed without and with cricoid pressure. Patients were allocated randomly into two groups: a gum elastic bougie or stylet group. One of the two devices was used for tracheal intubation while applying cricoid pressure. The duration and ease of tracheal intubation was recorded. MAIN RESULTS In 58 patients, the trachea was intubated at the first attempt. In the stylet group, tracheal intubation was difficult and needed more time, especially when the glottic opening was not visible. In the bougie group, the duration and ease of intubation was not influenced by laryngeal view. In the remaining two patients with Cook's modified 3b laryngeal view, it was impossible to intubate the trachea with these devices. CONCLUSIONS Applying cricoid pressure worsened laryngeal view. The use of a gum elastic bougie was more effective than the use of a stylet to facilitate intubation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Airway scope and gum elastic bougie with Macintosh laryngoscope for tracheal intubation in patients with simulated restricted neck mobility.

BACKGROUND /st> Airway Scope is a new videolaryngoscope which requires less cervical movement during intubation than direct laryngoscopy. Thus, in patients wearing a rigid cervical collar, we compared the efficacy of the Airway Scope and the gum elastic bougie with Macintosh laryngoscope during tracheal intubation. METHODS /st> Anaesthesia was induced with propofol, fentanyl, and rocuronium. ...

متن کامل

Utility of a Gum-Elastic Bougie for Difficult Airway Management in Infants: A Simulation-Based Crossover Analysis

BACKGROUND Direct laryngoscopy with the Miller laryngoscope (Mil) for infant tracheal intubation is often difficult to use even for skilled professionals. We performed a simulation trial evaluating the utility of a tracheal tube introducer (gum-elastic bougie (GEB)) in a simulated, difficult infant airway model. METHODS Fifteen anesthesiologists performed tracheal intubation on an infant mani...

متن کامل

[Comparison of different stylets used for intubation with the C-MAC D-Blade® Videolaryngoscope: a randomized controlled study].

OBJECTIVE The angle of the C-MAC D-Blade® videolaryngoscope, which is used for difficult airway interventions, is not compatible with routinely used endotracheal tubes. METHODS A prospective randomized crossover study was performed comparing five intubation methods for use with standardized airways, including using different stylets or no stylet: Group HS, hockey-stick stylet; Group DS, D-bla...

متن کامل

Fibre-optic aided bougie (FAB) for simulated difficult tracheal intubation.

INTRODUCTION Difficult intubation remains a key problem and the value of the gum elastic bougie as a first approach is well recognised. MATERIALS AND METHODS A fine fibre-optic endoscope (Rapiscope, Cook Critical Care) was used in 50 patients to verify placement of a custom-designed hollow plastic bougie prior to "rail-roading" a tracheal tube. Following induction and muscle relaxation, direc...

متن کامل

Comparison between bougies and stylets for simulated tracheal intubation with the C-MAC D-blade videolaryngoscope.

BACKGROUND The C-MAC D-blade is a new, highly angulated, videolaryngoscope blade designed for use in patients with difficult airways. Directing a tracheal tube into the trachea with any indirect viewing laryngoscope can be difficult, even with a good view of the laryngeal inlet. OBJECTIVE To determine which introducing strategy is most suitable for use with the C-MAC D-blade videolaryngoscope...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie

دوره 50 7  شماره 

صفحات  -

تاریخ انتشار 2003