Comparison of the long-term clinical results of hydrophilic and hydrophobic acrylic intraocular lenses.

نویسندگان

  • Youngwoo Suh
  • Chunghoon Oh
  • Hyo-Myung Kim
چکیده

This study was performed to compare the incidence of posterior capsular opacity (PCO) and refractive errors between hydrophilic (ACR6D, Corneal) and hydrophobic (MA60BM, AcrySof) acrylic intraocular lenses (IOLs) over a 3-year follow-up after phacoemulsification surgery. The patients with AcrySof implanted in one eye and Corneal in the other eye were categorized as Group 1 (n=28), while those with one or both eyes implanted with IOLs of the same kind were categorized as Group 2 (AcrySof, n=90; Corneal, n=95). Refractive errors were evaluated at 3 months and 3 years postoperatively. The incidence of visually significant PCO was investigated 3 years postoperatively. Postoperative refractive values at 3 months were not significantly different between the two groups. However, refractive values at 3 years were significantly different between two IOLs in both groups [AcrySof -0.37+/-0.43D, Corneal -0.62+/-0.58D in Group 1 (p=0.04); AcrySof -0.38+/-0.52, Corneal -0.68+/-0.54 in Group 2 (p<0.01)]. The incidence of visually significant PCO was 14% and 32% in Group 1, and 13% and 28% in Group 2, for the AcrySof and Corneal implants, respectively. The incidence of visually significant PCO of hydrophilic acrylic IOLs was higher than that of hydrophobic acrylic IOLs in the 3-year follow-up. The postoperative 3-year refractive value of Corneal showed myopic shift.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neodymium: YAG capsulotomy rates after phacoemulsification with hydrophobic and hydrophilic acrylic intraocular lenses.

PURPOSE To retrospectively evaluate the incidence of neodymium: YAG (ND:YAG) laser capsulotomies for posterior capsule opacification (PCO) seen with hydrophobic and hydrophilic acrylic intraocular lens implants 18 months after surgery. METHODS One hundred and five eyes that had phacoemulsification with a continuous curvilinear capsulorhexis and implantation of either a hydrophobic or a hydrop...

متن کامل

Comparison of clinical results between heparin surface modified hydrophilic acrylic and hydrophobic acrylic intraocular lens.

PURPOSE To compare the clinical results of heparin surface modified (HSM) hydrophilic acrylic intraocular lens (IOL) with those of hydrophobic acrylic IOL. METHODS One hundred patients with cataract were randomized to receive one of acrylic foldable IOLs after phacoemulsification: HSM hydrophilic acrylic IOL (n=50) BioVue3 (BioVue, OII, Ontario, CA, USA) and hydrophobic acrylic IOL (n=50) Sen...

متن کامل

Anterior Segment Intraocular Lens Edge Profiles of Currently Available Intraocular Lenses and Recent Improvements

We evaluated the microstructure of the edges of currently available foldable intraocular lenses (IOLs). The methodology used assisted an IOL manufacturer (Hoya, Japan) to optimise the edge profile of its lenses. Ten designs of hydrophobic acrylic, six designs of silicone and 24 designs of hydrophilic acrylic IOLs were imaged under scanning electron microscopy (SEM), and the photographs were imp...

متن کامل

Effect of four different intraocular lenses on posterior capsule opacification.

AIM To evaluate the impact of 4 different intraocular lenses (IOLs) on posterior capsule opacification (PCO) by comparing the neodymium: yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy rates. METHODS This retrospective study included 4970 eyes of 4013 cataract patients who underwent phacoemulsification and IOL implantation between January 2000 and January 2008 by the same surgeon at one cl...

متن کامل

Findings of an experimental study in a rabbit model on posterior capsule opacification after implantation of hydrophobic acrylic and hydrophilic acrylic intraocular lenses

PURPOSE Study on cell growth on the posterior capsule after implantation of hydrophobic acrylic (Acrysof SA 60 AT) and hydrophilic acrylic (Akreos Disc) intraocular lenses (IOL) in a rabbit model and comparison of posterior capsule opacification (PCO). METHODS Phacoemulsification was performed in 22 rabbit eyes, and two different IOL types (Acrysof SA60 AT and Akreos Disc) were implanted. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Korean journal of ophthalmology : KJO

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2005