Constructing a Real-Time Prescription Drug Monitoring System
نویسندگان
چکیده
OBJECTIVES The objective of this investigation was to demonstrate the possibility of the construction of a real-time prescription drug monitoring system (PDMOS) using data from the nationwide Drug Utilization Review (DUR) system in Korea. METHODS The DUR system collects information on drug prescriptions issued by healthcare practitioners and on drugs dispensed by pharmacies. PDMOS was constructed using this data. The screen of PDMOS is designed to exhibit the number of drug prescriptions, the number of prescriptions dispensed by pharmacies, and the dispensed prescription drug costs on a daily and weekly basis. Data was sourced from the DUR system between June 1, 2016 and July 18, 2016. The TOGA solution developed by the EYEQMC Co. Ltd. of Seoul, Korea was used to produce the screen shots. RESULTS Prescription numbers by medical facilities were more numerous than the number of prescriptions dispensed by pharmacies, as expected. The number of prescriptions per day was between 2 to 3 million. The prescriptions issued by primary care clinics were most numerous, at 75% of the total number of prescriptions. Daily prescription drug costs were found to be approximately US $50 million. The prescription drug costs were highest on Mondays and were reduced towards the end of the week. Prescriptions and dispensed prescriptions numbered approximately 1,200 and 1,000 million, respectively. CONCLUSIONS The construction of a real-time PDMOS has been successful to provide daily and weekly information. There was a lag time of only one day at the national level in terms of information extraction, and scarcely any time was required to load the data. Therefore, this study highlights the potential of constructing a PDMOS to monitor the estimate the number of prescriptions and the resulting expenditures from prescriptions.
منابع مشابه
Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals
Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...
متن کاملDesigning and Constructing Blood Flow Monitoring System to Predict Pressure Ulcers on Heel
Background: A pressure ulcer is a complication related to the need for the care and treatment of primarily disabled and elderly people. With the decrease of the blood flow caused by the pressure loaded, ulcers are formed and the tissue will be wasted with the passage of time.Objective the aim of this study was to construct blood flow monitoring system on the heel tissue which was under external...
متن کاملPrescription drug monitoring in Australia: capacity and coverage issues.
ecent years have seen increases in prescription of Rpharmaceutical opioids and benzodiazepines, and in the associated harms. This presents challenges for clinicians and governments regarding appropriate monitoring and responses. Real-time prescription drug monitoring programs (RT-PDMPs) are being considered in Australia to enable detection of drug diversion (when drugs are transferred from a li...
متن کاملReal-time acoustic tomography system and the experience of Caspian current sea monitoring
The Acoustic Tomography (AT) systems are used to monitor long-term and continuous flow in rivers, seas and oceans. One of the disadvantages of existing systems in Iran is the inability of real-time/automated measurements. In this study, by adding a raspberry Pi computer to the system and performing the required programming, it was possible to do online monitoring. The data are transferred to th...
متن کاملFeasibility Study of Real-time and Automated Monitoring of Iranian Rivers using 50-kHz Fluvial Acoustic Tomography System
Acoustic Tomography (AT) technique is an innovative method for real-time river monitoring. In this study, not only the accuracy of flow velocity measurement using 50 kHz AT system which is appropriate for narrow rivers (most Iranian rivers) is evaluated, but also its performance is compared with 30 kHz one which is used in wide rivers. The comparison results showed that the velocity resolutions...
متن کامل