The energy and electric field dependence of pulse shape discrimination in liquid xenon have been measured in a 10 gm two-phase xenon time projection chamber. We have demonstrated the use of the pulse shape and charge-to-light ratio simultaneously to obtain a leakage below that achievable by either discriminant alone. A Monte Carlo is used to show that the dominant fluctuation in the pulse shape quantity is statistical in nature, and project the performance of these techniques in larger detectors. Although the performance is generally weak at low energies relevant to elastic WIMP recoil searches, the pulse shape can be used in probing for higher energy inelastic WIMP recoils.
منابع مشابه
Dark Matter Search at Boulby Mine
The Boulby Dark Matter Collaboration (BDMC) is running a WIMP Dark Matter research programme in the underground laboratory of Boulby Mine. The two axes of the programme are based on (1) liquid Xenon (LXe) as the WIMP target and (2) directional detection in low pressure gas detectors. ZEPLIN-1 is a 3.1kg of LXe scintillation detector with a background discrimination based on Pulse Shape Analysis...
متن کاملWIMP Searches with Liquid Xenon: the XENON10 Experiment
The XENON experiment searches for Weakly Interacting Massive Particles (WIMPs) with liquid xenon (LXe) as the active target. The detector is a 3-D position sensitive Time Projection Chamber optimized to simultaneously measure the ionization and scintillation produced by a recoil event down to energies of 16 keV. The distinct ratio of the two signals for nuclear recoils arising from WIMPs and ne...
متن کاملA Study of the Scintillation Induced by Alpha Particles and Gamma Rays in Liquid Xenon in an Electric Field
Scintillation produced in liquid xenon by alpha particles and gamma rays has been studied as a function of applied electric field. For back scattered gamma rays with energy of about 200 keV, the number of scintillation photons was found to decrease by 64±2% with increasing field strength. Consequently, the pulse shape discrimination power between alpha particles and gamma rays is found to reduc...
متن کاملMeasurements of Scintillation Efficiency and Pulse-Shape for Low Energy Recoils in Liquid Xenon
Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 ± 0.01 in the recoil energy range 40 keV 70 keV. Under the assumption of a single dominant decay component to the scintillation pulse-shape the log-normal mean parameter T0 of the maximum likelihood estimator...
متن کاملR&D Results and Status of the XENON Dark Matter Experiment
The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xenon nuclei. With a fiducial mass of 1000 kg of liquid xenon, a sufficiently low threshold of 16 keV recoil energy and an unrejected background rate of 10 events per year, XENON would be sensitive to a WIMP-nucleon interaction cross secti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009