Allergen Micro-Bead Array for IgE Detection: A Feasibility Study Using Allergenic Molecules Tested on a Flexible Multiplex Flow Cytometric Immunoassay
نویسندگان
چکیده
BACKGROUND Allergies represent the most prevalent non infective diseases worldwide. Approaching IgE-mediated sensitizations improved much by adopting allergenic molecules instead of extracts, and by using the micro-technology for multiplex testing. OBJECTIVE AND METHODS To provide a proof-of-concept that a flow cytometric bead array is a feasible mean for the detection of specific IgE reactivity to allergenic molecules in a multiplex-like way. A flow cytometry Allergenic Molecule-based micro-bead Array system (ABA) was set by coupling allergenic molecules with commercially available micro-beads. Allergen specific polyclonal and monoclonal antibodies, as well as samples from 167 allergic patients, characterized by means of the ISAC microarray system, were used as means to show the feasibility of the ABA. Three hundred and thirty-six sera were tested for 1 or more of the 16 selected allergens, for a total number of 1,519 tests on each of the two systems. RESULTS Successful coupling was initially verified by detecting the binding of rabbit polyclonal IgG, mouse monoclonal, and pooled human IgE toward three allergens, namely nDer s 1, nPen m 1, and nPru p 3. The ABA assay showed to detect IgE to nAct d 1, nAct d 11, rAln g 1, nAmb a 1, nArt v 3, rBet v 1, rCor a 1, nCup a 1, nDer p 1, nDer s 1, rHev b 5, nOle e 1, rPar j 2, nPen m 1, rPhl p 1, and nPru p 3. Results obtained by ABA IgE testing were highly correlated to ISAC testing (r = 0.87, p<0.0001). No unspecific binding was recorded because of high total IgE values. CONCLUSION The ABA assay represents a useful and flexible method for multiplex IgE detection using allergenic molecules. As also shown by our initial experiments with monoclonals and polyclonals, ABA is suitable for detecting other human and non-human immunoglobulins.
منابع مشابه
Bead-based multianalyte flow immunoassays: the cytometric bead array system.
Analytical cytometry has significant potential beyond cellular analysis. The inherent capability of flow cytometers to efficiently discriminate between uniformly sized particles based on their intrinsic properties provides the foundation for multiplex bead assays. The technology can be exploited in designing immunoassays, Western blot-like antibody assays, and nucleic acid hybridization assays....
متن کاملMultiplex Cytokine Profiling of Stimulated Mouse Splenocytes Using a Cytometric Bead-based Immunoassay Platform
Bead-based immunoassays employ the same basic principle as sandwich immunoassays. Capture beads, which can be differentiated by size and internal allophycocyanin (APC) fluorescence intensity, are conjugated to antibodies specific to a particular analyte. Next, a selected panel of defined capture bead sets is incubated with a biological sample containing target analytes specific to the capture a...
متن کاملAn automated microfluidic-based immunoassay cartridge for allergen screening and other multiplexed assays.
A microfluidic cartridge and system for multiplexed immunoassays is described. The passive microfluidic cartridge was composed of three layers of injection molded plastic sealed together using a thermal staking technique. Using this platform technology, a specific immunoglobulin E (IgE) panel assay was constructed. Allergen extract targets, positive and negative controls, and IgE calibration st...
متن کاملReal-Life Study for the Diagnosis of House Dust Mite Allergy - The Value of Recombinant Allergen-Based IgE Serology.
BACKGROUND Dermatophagoides pteronyssinus is one of the most important perennial allergen sources worldwide. Molecular diagnostics using the commercially available major allergens (Der p 1 and Der p 2) in combination with Der p 10 do not detect house dust mite (HDM) sensitization in a number of cases when used alone. The objective was to evaluate the IgE reactivity profiles of these patients us...
متن کاملThe IgE-facilitated allergen binding (FAB) assay: validation of a novel flow-cytometric based method for the detection of inhibitory antibody responses.
The IgE-facilitated allergen binding (IgE-FAB) assay represents an in vitro model of facilitated allergen presentation. Allergen-IgE complexes are incubated with an EBV-transformed B cell line and complexes bound to CD23 on the surface of cells are detected by flow cytometry. The addition of serum from patients who have received allergen-specific immunotherapy has been shown previously to inhib...
متن کامل