Bone weakness after the removal of plates and screws. Cortical atrophy or screw holes?

نویسندگان

  • J Rosson
  • J Egan
  • J Shearer
  • P Monro
چکیده

Bone weakness leading to refracture is a recognised complication of the removal of rigid fixation plates. We have used partially demineralised rabbit tibiae to simulate atrophic changes and to determine whether weakness is due to atrophy or to residual screw holes. Partial demineralisation and a screw hole each reduced maximum bending moment. However, energy absorbing capacity was little affected by demineralisation, but was reduced to 50% by a single drill hole. Residual screw holes are a considerably more important cause of bone weakness after plate removal than is cortical atrophy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Locking Self-Taping Bone Screws for Angularly Stable Plates

Paper focuses on biomechanics, specifically on locking cortical bone screws in angularly stable plates used for the treatment of bone fractures in the medical fields of traumatology and orthopaedics. During extraction of titanium-alloy implants, problems are encountered in an effort to loosen some locking bone screws from the locking holes of an angularly stable plate and the subsequent strippi...

متن کامل

Analysis of complications after reconstruction of bone defects involving complete mandibular resection using finite element modelling.

BACKGROUND In a retrospective study, risk factors for complications after the bridging of mandibular defects using reconstruction plates were reviewed. Especially the loosening of the plate-screw-mandible complex should be analyzed with a finite element model in order to reduce plate complications in future. PATIENTS AND METHODS We examined 60 patients who underwent a treatment with reconstru...

متن کامل

An investigation of tensile strength of Ti6Al4V titanium screw inside femur bone using finite element and experimental tests

The geometric optimization of orthopedic screws can considerably increase their orthopedic efficiency. Due to the high geometric parameters of orthopedic screws, a finite element simulation is an effective tool for analyzing and forecasting the effect of the parameters on the load-bearing capacity of different types of screws and bones. Thus, in the present study, the tensile strength of a typi...

متن کامل

Resorbable fillers reduce stress risers from empty screw holes.

BACKGROUND Empty screw holes after hardware removal are stress risers that weaken bone and can lead to refracture in an active individual. We sought to reduce these stress risers. We hypothesize that resorbable screws used as hole fillers would (1) provide immediate strength and (2) maintain this strength during resorption. METHODS Randomized, prospective controlled animal laboratory study wi...

متن کامل

Analysis on Biomechanical Characteristics of Shape Memory Alloy Fixation Grip for Femoral Fractures

As life the expectancy has increased with the advancement of medical technology, the frequency of femur fractures has also increased. The conventional treatment utilizes a bone fixation plate and screw system. However, because the screws are inserted into directly into the bones, it can cause bones to get crushed and leave holes during removal of the screws. For the reasons above, secondary fra...

متن کامل