The Proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice.

نویسندگان

  • Tara L Alvarez
  • Stephen A Gollance
  • Gordon A Thomas
  • Richard J Greene
  • Peter M Marchetto
  • Eugene J Moore
  • Tony Realini
  • Jeffrey M Liebmann
  • Robert Ritch
  • Paul Lama
  • Robert D Fechtner
چکیده

PURPOSE To evaluate the Proview Eye Pressure Monitor as a medical instrument and as a technique for enabling a patient to obtain an accurate measure of his or her intraocular pressure (IOP). DESIGN An experimental laboratory evaluation and an independent prospective clinical study to test the reproducibility and accuracy of the Proview technique relative to Goldmann applanation tonometry. PARTICIPANTS For the laboratory study, we analyzed 3 tonometers, each packaged as a Proview Eye Pressure Monitor by Bausch & Lomb. In the independent prospective experimental study, 137 subjects participated, consisting of healthy volunteers and glaucoma patients. METHODS For laboratory testing, we held each tonometer with a micrometer to assure controlled positioning and pressed its sensing tip against a force meter that produced a calibrated, digital force reading. For clinical testing, we taught subjects (n = 137) to use the Proview technique in accordance with the manufacturer's instructions. Each subject obtained 5 measurements with each of the 5 different Proview devices. A clinician measured the IOP using Goldmann applanation tonometry. MAIN OUTCOME MEASURES We measured the absolute value, linearity, and repeatability of the force meter readings on the tonometers during the instrument laboratory evaluation. The accuracy was evaluated by comparing the Proview measurements to the Goldmann applanation measurements. Reproducibility of clinical Proview measurements was also measured. All measurements were in mmHg during the clinical evaluation. RESULTS Laboratory: There was a linear relationship between the pressures read by the Proview tonometers and known forces. The Proview tonometers read the maximum pressure applied. Clinical: The Proview technique is simple to use because it was comfortable and reproducible, with an average variance of the measurements by the same patient of 3.4 mmHg(2). Other variables besides IOP seem to affect the Proview pressure measurements, as seen in the large scatter in our data, measured by our correlation coefficient of r = 0.41. The sensitivity of the Proview technique to detect patients with high IOP (which we defined as a Goldmann pressure of >/=22 mmHg) is low; the Proview pressure identified only 18% (4/22) of these patients. CONCLUSIONS The Proview instrument and technique were reproducible. However, the Proview tonometer seems not to be reliable as an indicator of IOP. The sensitivity for detecting high IOP was low in this cohort, and the agreement with Goldmann applanation was poor for some individuals. This brings into question the underlying assumption that a force proportional to the IOP generates phosphenes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Error Measurement for a Portable Tonometer

Most patients with glaucoma exhibit elevated intraocular pressure (IOP). A cost effective device that allows the patient to measure IOP at regular intervals may reduce vision loss. This research tested the Bausch & Lomb Proview self tonometer against a calibrated force meter. It further compared the Proview tonometer with results from the clinical gold standard, the Goldmann tonometer. Results ...

متن کامل

Clinical evaluation of the pressure phosphene tonometer in patients with glaucoma.

AIM To evaluate the reliability of the pressure phosphene tonometer in comparison with the Goldmann applanation tonometer. METHODS 45 consecutive patients with glaucoma (78 eyes) participated in the study. Eyes with previous eye surgery, a documented peripheral visual field defect, a refractive error of more than 5 dioptres, and patients who were unable to understand the procedure were exclud...

متن کامل

Pressure phosphene self-tonometry: a comparison with goldmann tonometry in glaucoma patients.

PURPOSE To evaluate whether the pressure phosphene tonometer (PPT) is suitable for self-tonometry in patients with glaucoma or ocular hypertension. METHODS This was a prospective comparative study of 102 eyes of 102 patients with chronic glaucoma or ocular hypertension. Intraocular pressure (IOP) measurements by the Goldmann tonometer (GT) were compared with self-measured readings with the PP...

متن کامل

بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن

To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...

متن کامل

Pressure measurement: which tonometer?

In the search for more accurate ways to determine intraocular pressure, the Halberg applanation tonometer may represent an alternative to the Schi0tz tonometer for routine screening pressure measurements. Although between 100 to 150 measurements are generally required to gain proficiency with the Halberg, the instrument is accurate in patients with normal corneas even with very abnormal scleral...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 111 6  شماره 

صفحات  -

تاریخ انتشار 2004