Assessing the Performance of LiF:Mg,Ti and LiF:Mg,Cu,P Extremity Dosemeters

نویسندگان

  • Luís C. Freire
  • Ana Calado
  • Miguel Pereira
  • Luís Santos
  • João Cardoso
  • João G. Alves
چکیده

In this paper, we present the results aimed at assessing the performance of two varieties of LiF detectors (LiF:Mg,Ti and LiF:Mg,Cu,P, of the EXTRAD type), relatively to reproducibility, detection threshold and angular dependence criteria defined in the ISO 12794:2000 Standard and other documents. The fading properties of these two dosemeter varieties were also investigated. In all experiments, five or eight dosemeters of each LiF variety were randomly selected out of the respective batches, which comprise one hundred dosemeters each. In all experiments, the LiF:Mg,Ti and the LiF:Mg,Cu,P dosemeters were simultaneously submitted to the same steps (pre-irradiation treatment, irradiation and readout) in order to guarantee the direct comparison of the results. Reproducibility was assessed by irradiating sets of five dosemeters of each LiF variety with a 90Sr_90y source built-in one Harshaw 6600 reader. On the other hand, the detection threshold was investigated based on the above mentioned standard. The assessment of the isotropy criterion was done by irradiating four sets of five dosemeters of each LiF variety with a N-80 beam (mean energy of 65 keV), at different angles of incidence, namely 0°, ±20°, ±40° and ±60° and the response was calculated relatively to a Cs reference beam. The fading properties of both LiF varieties were evaluated by comparing the signal yielded by dosemeters of each LiF variety irradiated to a reference dose at different stages relatively to storage, comprising sets stored after (SA) and stored before (SB) irradiation. Increasing periods of 2, 4, 6 and 8 weeks, similar to the ones used in routine monitoring, were considered. For the reproducibility and detection threshold performance tests, the ISO 12794:2000 Standard defines acceptance limits of 10% and 1 mSv, respectively. For the isotropy performance test, an isotropy coefficient is defined, and verified, if it yields values comprised in the 0.85-1.15 range. On the other way, Portuguese legislation defines that the fading effects shall be lower than 10% per month (Decreto-Lei 167/2002). The reproducibility results yielded values below 2.01% and 1.65% for LiF:Mg,Ti and LiF:Mg,Cu,P dosemeters respectively, which are well below the 10% limit mentioned before. In terms of detection threshold, the evaluated values for each LiF variety are comprised between 0.08 and 0.17 mSv for LiF:Mg,Ti and between 0.53 and 0.85 mSv for LiF:Mg,Cu,P, also below the 1 mSv limit. P r e s e n t i n g au tho r , E m a i l : l f r e i r e @ i t n . p t The angular dependence was verified for both dosemeter types, for all the irradiation angles. The isotropy coefficients are comprised between 0.96 and 0.99 for LiF:Mg,Ti and between 0.94 and 0.98 for LiF:Mg,Cu,P, well within the limits. Finally, the fading experiment showed that LiF:Mg,Cu,P dosemeters have a lower fading effect than LiF:Mg,Ti ones (monthly values respectively between 0.7 and 3.8%, and 4.2 and 21.4%). The results show that both LiF varieties are well-suited for extremity monitoring. However, previous studies and the fading properties of LiF:Mg,Cu,P dosemeters re-inforce the idea that LiF:Mg,Cu,P is best suited for this purpose provided the residual signal is kept under control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modification of shirt buttons for retrospective radiation dosimetry after a radiological event.

Preliminary results are presented for a personal radiation dosimeter in the form of a clothing button to provide gamma-ray dose estimation for clinically-significant external radiation exposures to the general public due to a radiological incident, such as use of a radiological dispersal device. Rods of thermoluminescent material (LiF:Mg,Ti and LiF:Mg,Cu,P) were encapsulated in plastic "buttons...

متن کامل

بررسی اثر رژیم گرمایی روی طیف تابش LiF:Mg,Cu,P و مقایسه با LiF:P

Thermoluminescence material LiF:Mg,Cu,P was produced using standard GR200 dopant concentrations and its emission and absorption spectrums was measured after beta irradiation. The alterations resulting from various thermal treatments, excessing the recommended temperatures namely 240ºC on the emission and absorption spectrums has been investigated. The main peak of absorption spectrum, which is ...

متن کامل

بررسی و تحلیل منحنی‏های پاسخ پودر فلورید لیتیوم (LiF:Mg,Ti) در مش‏های مختلف برای پرتو گاما به‌ منظور استفاده در دزیمتری ترمولومینسانس

The effect of the different parameters on the thermoluminescence behavior of LiF:Mg,Ti powder produced by melting method is reported. Standard powder of LiF:Mg,Ti manufactured by Harshaw company, was converted to smaller grains size, to obtain different meshes after melting and cooling steps. Powder in this study are of mesh size: 80 to 100, 120 to 140 and 170 to 200 µm. The results show that ...

متن کامل

Dosimetry at the Portuguese research reactor using thermoluminescence measurements and Monte Carlo calculations.

This work presents an extensive study on Monte Carlo radiation transport simulation and thermoluminescent (TL) dosimetry for characterising mixed radiation fields (neutrons and photons) occurring in nuclear reactors. The feasibility of these methods is investigated for radiation fields at various locations of the Portuguese Research Reactor (RPI). The performance of the approaches developed in ...

متن کامل

13 USING NATURAL LUMINESCENT MATERIALS AND HIGHLY SENSITIVE SINTERED DOSIMETERS MCP-N (LiF:Mg,Cu,P) IN RADIATION DOSIMETRY

The main trend in radiation dosimetry nowadays is the use of solid state detectors. Luminescent dosimetric techniques are part of this field. This paper aims to present the application of thermoluminescence as a tool in measuring natural nuclear radiation, namely the application of highly sensitive sintered dosimeters MCP-N (LiF:Mg,Cu,P) in environmental monitoring and the possibility of using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011