[Comparison of dynamic contour tonometry (Pascal) with pneumotonometry and Goldmann tonometry].
نویسندگان
چکیده
PURPOSE To compare the intraocular pressure measurements as defined by the Pascal tonometer, the Goldmann tonometer and the pneumotonometer. METHODS This was an observational clinical study, which included two hundred and five randomly selected subjects recruited from the Ophthalmology Department. The intraocular pressure measurements were performed with each tonometry technique in a randomized order. RESULTS The Pascal's intraocular pressure measurement was significantly higher than that measured by the other two tonometers (p<0.05). The quality data of Pascal was: optimum in 27.3% (56 of 205 patients), acceptable in 42% (86 of 205 patients) and unacceptable in 23.4% (48 of 205 patients). In 7.3% (15 of 205 patients) it was impossible to obtain any measurement using Pascal. A weak correlation coefficient between the Pascal and the Goldmann, and between Pascal and the pneumotonometer was found. The Bland-Altman method of measurement using these tonometers showed a high degree of discordance. CONCLUSION As reported by others authors, the Pascal's intraocular pressure measurement is higher than that of the Goldmann tonometer. The measurement differs from 0.7 to 4.4 mmHg. In corneas with pathology, it is very difficult or even unacceptable to measure the intraocular pressure using the Pascal tonometer.
منابع مشابه
History and Clinical Validation of the PASCAL Dynamic Contour Tonometer
Will Goldmann applanation tonometry, the age old “gold standard” of intraocular pressure (IOP) measurement, be replaced with newer methods? One of the newer methods of IOP measurement is PASCAL dynamic contour tonometry (DCT). A review of the history, scientific principles, clinical validation and clinical utility of DCT is presented.
متن کاملDynamic Contour Tonometry, Tono-Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral Intraocular Pressure (IOP) Measurements in Patients with Corneal Pathologies
Unspecified Posted at the Zurich Open Repository and Archive, University of Zurich ZORA URL: http://doi.org/10.5167/uzh-101903 Published Version Originally published at: Neuburger, M; Grosswendt, J; Lautebach, S; Maier, P; Birnbaum, F; Böhringer, D; Funk, J; Jordan, J F; Reinhard, T (2014). Dynamic Contour Tonometry, Tono-Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral...
متن کاملComparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature
PURPOSE The aim of the study was to assess the influence of central corneal thickness (CCT) and corneal curvature in tonometry measurements taken by Goldmann applanation tonometry (GAT) and Pascal dynamic contour tonometry (DCT). METHODS This was a prospective study of 185 eyes from 97 subjects, attending outpatient ophthalmology appointments, who underwent intraocular pressure measurements b...
متن کاملDynamic contour tonometry versus Goldmann applanation tonometry: challenging the gold standard
متن کامل
Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archivos de la Sociedad Espanola de Oftalmologia
دوره 82 6 شماره
صفحات -
تاریخ انتشار 2007