An in vitro and in vivo validation of a novel color-coded syringe device for measuring the intracuff pressure in cuffed endotracheal tubes.
نویسندگان
چکیده
BACKGROUND The clinical practice of pediatric anesthesiology has changed with a transition to the use of cuffed endotracheal tubes (ETTs) in infants and children. The monitoring of intracuff pressure has been suggested as one means to limit the potential for damage to the tracheal mucosa. The current study evaluates the accuracy of a novel, color-coded syringe device which provides three zones (green, clear, and red) to estimate the intracuff pressure. METHOD The study was conducted in two phases. Phase 1 was an in vitro study where cuffed ETTs of sizes 4.0 mm, 5.0 mm and 6.0 mm ID were placed into polyvinylchloride tubing of appropriate sizes. A manometer and the syringe device were simultaneously attached to measure the intracuff pressure at the middle of the 3 different zones on the device (red, clear, and green). Phase 2 was an in vivo study where the syringe device and the manometer were simultaneously attached to the pilot balloon to measure the intracuff pressure and the corresponding zone on the color-coded syringe following endotracheal intubation. Statistical analysis included a descriptive reporting of the mean ± SD, median, range, and 95% confidence intervals (CI) of the actual intracuff pressure readings at the three zones of the syringe device during both its in vitro and in vivo use. RESULTS For phase 1 of the study, the 95% CI for the green, clear, and red zones were 21.5-21.8, 29.2-29.5, and 46.5-47.4 cmH2O respectively. This correlated well with the manufacturer reported values of 20-30, 30-40, and 40-60 cmH2O for the 3 zones (green, clear, and red respectively). Phase 2 of the study included 200 patients ranging in age from 0.1 to 21.8 years (6.7 ± 5.1 years) and in weight from 4.0 to 129.1 kilograms (29.4 ± 23.3 kgs). The size of the ETTs ranged from 3.0 to 7.0 mm ID. The intracuff pressure measured by the manometer ranged from 4 to 65 cmH2O (27.6 ± 9.7 cmH2O). The 95% CI for the green, clear, and red zones were 20.5-21.7, 27.7-29.1, and 41.2-46.5 cmH2O respectively. There was no significant differences noted when comparing different patient ages or sizes of ETT. CONCLUSION The current study demonstrates a clinically acceptable correlation between the zones on this novel, color-coded syringe device and the actual measurement of the intracuff pressure obtained by a manometer for both in vitro and in vivo use. This device is a simple, reliable, portable and affordable method to monitor intracuff pressure.
منابع مشابه
An in vitro and in vivo validation of a novel monitor for intracuff pressure in cuffed endotracheal tubes.
BACKGROUND The clinical practice of pediatric anesthesiology has changed with increasing use of cuffed endotracheal tubes (cETTs) in infants and children. To limit the risk of tracheal mucosal damage, regular monitoring of intracuff pressure (CP) is necessary. This study evaluates the efficacy and accuracy of a novel syringe device that provides a digital readout of the CP. METHODS The study ...
متن کاملPediatric cuffed endotracheal tubes: an evolution of care.
PURPOSE To examine the history of pediatric endotracheal intubation and the issues surrounding the change from uncuffed endotracheal tubes to cuffed endotracheal tubes, including pediatric airway anatomy, endotracheal tube design, complications, and safety concerns. METHOD Review of the literature. CONCLUSIONS Although the use of cuffed endotracheal tubes in infants and children remains a t...
متن کاملPediatric airway anatomy may not be what we thought: implications for clinical practice and the use of cuffed endotracheal tubes.
One of the long held tenets of pediatric anesthesia has been the notion that the pediatric airway is conical shape with the narrowest area being the cricoid region. However, recent studies using radiologic imaging techniques (magnetic resonance imaging and computed tomography) or direct bronchoscopic observation have questioned this suggesting that the narrowest segment may be at or just below ...
متن کاملThe value of polyurethane-cuffed endotracheal tubes to reduce microaspiration and intubation-related pneumonia: a systematic review of laboratory and clinical studies
BACKGROUND When conventional high-volume, low-pressure cuffs of endotracheal tubes (ETTs) are inflated, channel formation due to folds in the cuff wall can occur. These channels facilitate microaspiration of subglottic secretions, which is the main pathogenic mechanism leading to intubation-related pneumonia. Ultrathin polyurethane (PU)-cuffed ETTs are developed to minimize channel formation in...
متن کاملThe effect of cuffed endotracheal tube on respiratory complication following adenotonsillectomy in children
Abstract Background: Uncuffed endotracheal tube(ETT) were considered for children less than 8 years. Meanwhile, aspiration around ETT in patients undergoing adenotonsillectomy is concerned.We compared cuffed versus uncuffed ETT regarding respiratory complications following adenotonsillectomy. Methods: 128 children aged 2-8 yr were divided to two groups of 64 each. Uncuffed and cuffed tubes w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of clinical and experimental medicine
دوره 8 7 شماره
صفحات -
تاریخ انتشار 2015