A Portable VolumejFlow Calibrating Syringe*

نویسنده

  • John W. Shigeoka
چکیده

Two samples of a manual 3 L calibrating syringe which displays an electronically calculated FEF25-75% were evaluated to determine its suitability as a flow calibrator were evaluated. Room air was discharged into a manual spirometer system known to be accurate. The calibrator-determined values correlated very closely with the spirometer values over an FEF25-75 % range of 0.4 to 9 L/sec. The differences between calibrator and spirometer FEF2S-75% values were small (mean ± 1 percent, greatest 3.7 percent) and of little importance

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of Contemporary

A comprehensive evaluation of 62 spirometers from 37 different sources was performed using a two-part protocol: calibrated syringe, and dynamic waveform testing. All testingwas done with ambient air. Calibrated syringe testing examined the ability of the spirometers to accurately measure the output of a 3 L calibrating syringe under varying conditions. The accuracy, FVC volume linearity, and st...

متن کامل

Hand-held syringe as a portable plastic pump for on-chip continuous-flow PCR: miniaturization of sample injection device.

On-chip continuous-flow polymerase chain reactions (PCRs) generally require peripheral apparatus such as a pump for injecting a sample liquid into the fluidic channel. This makes the overall instrumentation bulky, limiting integration. In this study, we propose a new scheme for injecting a sample employing a hand-held syringe as a portable plastic pump, and apply it to an on-chip continuous-flo...

متن کامل

Syringe-vacuum microfluidics: A portable technique to create monodisperse emulsions.

We present a simple method for creating monodisperse emulsions with microfluidic devices. Unlike conventional approaches that require bulky pumps, control computers, and expertise with device physics to operate devices, our method requires only the microfluidic device and a hand-operated syringe. The fluids needed for the emulsion are loaded into the device inlets, while the syringe is used to ...

متن کامل

Fully Automated Self-calibrating Hybrid Flow Analyzer for Gaseous Formaldehyde

We report fully automated self-calibrating formaldehyde analyzers relying on a hybrid flow format and include operational scheme and design details. Long-term operation is made possible with the use of syringe pumps. Four identical analyzers were built and showed low LODs of 120 pptv or better (S/N =3) and good linearity over 0-50 ppbv HCHO concentration range (r > 0.9960). The analyzer can res...

متن کامل

NUCLEAR PHARMACY Dose from Syringe Procedures During Technetium-99m Radiopharmaceutical Preparation

We examined the dose from mTc contained in syringes and shielded vials to assess in detail the dose burdens in a central pharmacy. Methods: Absorbed-dose rates at the end of the plunger of a shielded syringe, when mTc is contained either in the syringe or in a shielded vial from which the activity would be drawn, were measured with CaF2 dosimeters. The dose rates also were calculated with a Mon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006