Polygonal Heat Conductors with a Stationary Hot Spot
نویسندگان
چکیده
We consider a convex polygonal heat conductor whose inscribed circle touches every side of the conductor. Initially, the conductor has constant temperature and, at every time, the temperature of its boundary is kept at zero. The hot spot is the point at which temperature attains its maximum at each given time. It is proved that, if the hot spot is stationary, then the conductor must satisfy two geometric conditions. In particular, we prove that these geometric conditions yield some symmetries provided the conductor is either pentagonal or hexagonal.
منابع مشابه
Simulation of Subcooled Flow Boiling Occurring in Internal Combustion Engine Water Jacket by Numerical Modeling in a Channel with Hot Spot
Boiling heat transfer always has been proposed as a solution for enhancing heat transfer between the fluid and solid surfaces. Subcooled flow boiling is one of the mechanisms that occur in Internal Combustion Engine water jacket in which high amounts of heat is transferred. In this research, it has been tried to simulate subcooled flow boiling in a geometry similar to coolant channel inside the...
متن کاملApplication of Combustion Hot Spot Analysis to Process Furnace with Arbor Coils
Hot spots are among the most serious operational issues in furnaces as they may result in the destruction of tubes. Hence, it is essential to locate such hot spots precisely on the tube surfaces inside the industrial furnaces in order to secure a safe design and operation. In the current study, we have extended the model proposed by Talmor in order to precisely locate the combustion hot spots o...
متن کاملApplication of Combustion Hot Spot Analysis to Process Furnace with Arbor Coils
Hot spots are among the most serious operational issues in furnaces as they may result in the destruction of tubes. Hence, it is essential to locate such hot spots precisely on the tube surfaces inside the industrial furnaces in order to secure a safe design and operation. In the current study, we have extended the model proposed by Talmor in order to precisely locate the combustion hot spots o...
متن کاملHottest Spot and Life Evaluation of Power Transformer Design Using Finite Element Method
Power transformers represent the largest portion of capital investment in transmission and distribution substations. In addition, power transformer outages have a considerable economic impact on the operation of an electrical network. One of the most important parameters’ governing a transformer’s life expectancy is the hot-spot temperature value. Due to under estimation of stray losses in powe...
متن کاملIdealized Hot Spot Experiments with a General Circulation Model
Idealized experiments are conducted using a GCM coupled to a 20-m slab ocean model to examine the short-term response to an initial localized positive equatorial SST anomaly, or “hot spot.” A hot spot is imposed upon an aquaplanet with globally uniform 28°C SST, insolation, and trace gas concentrations designed to mimic tropical warm pool conditions. No boundary condition or external parameter ...
متن کامل